Back to Search
Start Over
A new continuous-flow solar water disinfection system inactivating cysts of Acanthamoeba castellanii, and bacteria.
- Source :
-
Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology [Photochem Photobiol Sci] 2021 Jan; Vol. 20 (1), pp. 123-137. Date of Electronic Publication: 2021 Jan 25. - Publication Year :
- 2021
-
Abstract
- Solar water disinfection (SODIS) is an effective and inexpensive microbiological water treatment technique, applicable to communities lacking access to safely managed drinking water services, however, the lower volume of treated water per day (< 2.5 L per batch) is a limitation for the conventional SODIS process. To overcome this limitation, a continuous-flow solar water disinfection system was developed and tested for inactivation of Acanthamoeba castellanii cysts and Escherichia coli, Salmonella Typhimurium, Enterococcus faecalis, and Pseudomonas aeruginosa. The system consisted of a solar heater composed of a cylindrical-parabolic concentrator and a UV irradiator formed by a fresnel-type flat concentrator combined with a cylindrical-parabolic concentrator. Deionized water with low or high turbidity (< 1 or 50 nephelometric turbidity unit (NTU) where previously contaminated by 10 <superscript>8</superscript>  Cysts/L or 10 <superscript>5</superscript> -10 <superscript>6</superscript>  CFU/mL of each of four bacterial species. Then was pumped from the heating tank flowing through the heater and through the UV irradiator, then returning to the heating tank, until reaching 45, 55, 60 or 70 °C. The water was kept at the desired temperature, flowing through the UV irradiator for 0.5 and 10 min. Trophozoites were not recovered from cysts (during 20 days of incubation) when water with < 1 NTU was exposed to UV and 60 °C for 0.5 min. In water with 50 NTU, the same result was obtained after 10 min. In water with < 1 NTU, the inactivation of all bacteria was achieved when the water with < 1 NTU was exposed to 55 °C and UV for 0.5 min; in water, with 50 NTU the same result was achieved by exposure to 60 °C and UV for 0.5 min. The prototype processes 1 L of water every 90s. The system is effective and has the potential to be applied as an alternative to the large-scale public drinking water supply.
Details
- Language :
- English
- ISSN :
- 1474-9092
- Volume :
- 20
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology
- Publication Type :
- Academic Journal
- Accession number :
- 33721244
- Full Text :
- https://doi.org/10.1007/s43630-020-00008-4