Femoral artery cannulation as a safe alternative for aortic dissection arch repair in the era of axillary artery cannulation.
- Source :
-
Journal of thoracic disease [J Thorac Dis] 2021 Feb; Vol. 13 (2), pp. 671-680. - Publication Year :
- 2021
-
Abstract
- Background: To evaluate the safety and efficacy of femoral artery cannulation as an alternative to axillary artery cannulation, we retrospectively compared outcomes between patients with axillary or femoral artery cannulation during open aortic arch repair for type A aortic dissection (TAAD).<br />Methods: Between January 2014 and January 2019, 646 patients underwent open aortic arch repair with circulatory arrest for TAAD using antegrade selective cerebral perfusion (SACP) and were divided into two groups according to the site of arterial cannulation: an axillary artery group (axillary group, n=558) or a femoral artery group (femoral group, n=88). The axillary artery was considered as the primary cannulation site, and the femoral artery was used as an alternative when axillary artery cannulation was deemed unsuitable or had failed. Propensity score matching was performed to correct baseline differences.<br />Results: After propensity score matching, the patients' characteristics were comparable between groups (n=85 in each). The incidence of in-hospital mortality (10.6% vs. 14.1%; P=0.642) and stroke (3.5% vs. 5.9%; P=0.720) were comparable between the axillary and femoral groups. The incidence of newly required dialysis was lower in the femoral group, but the difference was not statistically significant (34.1% vs. 20.0%; P=0.050). Other outcomes and major adverse events were comparable.<br />Conclusions: Femoral artery cannulation produced similar perioperative outcomes to axillary cannulation after open arch repair for TAAD. The femoral artery can be used as a safe and effective alternative to the axillary artery for arterial cannulation in TAAD patients undergoing open arch repair.<br />Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/jtd-20-2113). The authors have no conflicts of interest to declare.<br /> (2021 Journal of Thoracic Disease. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2072-1439
- Volume :
- 13
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of thoracic disease
- Publication Type :
- Academic Journal
- Accession number :
- 33717540
- Full Text :
- https://doi.org/10.21037/jtd-20-2113