Back to Search
Start Over
Competing risks in patients with primary prevention implantable cardioverter-defibrillators: Global Electrical Heterogeneity and Clinical Outcomes study.
- Source :
-
Heart rhythm [Heart Rhythm] 2021 Jun; Vol. 18 (6), pp. 977-986. Date of Electronic Publication: 2021 Mar 06. - Publication Year :
- 2021
-
Abstract
- Background: Global electrical heterogeneity (GEH) is associated with sudden cardiac death in the general population. Its utility in patients with systolic heart failure who are candidates for primary prevention (PP) implantable cardioverter-defibrillators (ICDs) is unclear.<br />Objective: The purpose of this study was to investigate whether GEH is associated with sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies in patients with heart failure and PP ICDs.<br />Methods: We conducted a multicenter retrospective cohort study. GEH was measured by spatial ventricular gradient (SVG) direction (azimuth and elevation) and magnitude, QRS-T angle, and sum absolute QRST integral on preimplant 12-lead electrocardiograms. Survival analysis using cause-specific hazard functions compared the strength of associations with 2 competing outcomes: sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies and all-cause death without appropriate ICD therapies.<br />Results: We analyzed 2668 patients (mean age 63 ± 12 years; 624 (23%) female; 78% white; 43% nonischemic cardiomyopathy; left ventricular ejection fraction 28% ± 11% from 6 academic medical centers). After adjustment for demographic, clinical, device, and traditional electrocardiographic characteristics, SVG elevation (hazard ratio [HR] per 1SD 1.14; 95% confidence interval [CI] 1.04-1.25; P = .004), SVG azimuth (HR per 1SD 1.12; 95% CI 1.01-1.24; P = .039), SVG magnitude (HR per 1SD 0.75; 95% CI 0.66-0.85; P < .0001), and QRS-T angle (HR per 1SD 1.21; 95% CI 1.08-1.36; P = .001) were associated with appropriate ICD therapies. Sum absolute QRST integral had different associations in infarct-related cardiomyopathy (HR 1.29; 95% CI 1.04-1.60) and nonischemic cardiomyopathy (HR 0.78; 95% CI 0.62-0.96) (P <subscript>interaction</subscript> = .022).<br />Conclusion: In patients with PP ICDs, GEH is independently associated with appropriate ICD therapies. The SVG vector points in distinctly different directions in patients with 2 competing outcomes.<br /> (Copyright © 2021 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Death, Sudden, Cardiac epidemiology
Death, Sudden, Cardiac etiology
Female
Heart Failure, Systolic therapy
Humans
Male
Middle Aged
Retrospective Studies
Risk Factors
Survival Analysis
Survival Rate trends
United States epidemiology
Death, Sudden, Cardiac prevention & control
Defibrillators, Implantable
Heart Failure, Systolic complications
Primary Prevention methods
Risk Assessment methods
Subjects
Details
- Language :
- English
- ISSN :
- 1556-3871
- Volume :
- 18
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Heart rhythm
- Publication Type :
- Academic Journal
- Accession number :
- 33684549
- Full Text :
- https://doi.org/10.1016/j.hrthm.2021.03.006