Back to Search Start Over

Usefulness of Rhythm Monitoring Following Acute Ischemic Stroke.

Authors :
Khurshid S
Li X
Ashburner JM
Lipsanopoulos ATT
Lee PR
Lin AK
Ko D
Ellinor PT
Schwamm LH
Benjamin EJ
Atlas SJ
Singer DE
Anderson CD
Trinquart L
Lubitz SA
Source :
The American journal of cardiology [Am J Cardiol] 2021 May 15; Vol. 147, pp. 44-51. Date of Electronic Publication: 2021 Feb 20.
Publication Year :
2021

Abstract

We characterized monitor utilization in stroke survivors and assessed associations with underlying clinical atrial fibrillation (AF) risk. We retrospectively analyzed consecutive patients with acute ischemic stroke 10/2018-6/2019 without prevalent AF and assessed the 6-month incidence of monitor utilization (Holter/ECG, event/patch, implantable loop recorder [ILR]) using Fine-Gray models accounting for the competing risk of death. We assessed for predictors of monitor utilization using cause-specific hazards regression adjusted for the Cohorts for Heart and Aging Research in Genomic Epidemiology AF (CHARGE-AF) score, stroke subtype, and discharge disposition. Of 493 patients with acute ischemic stroke (age 65±16; 47% women), the 6-month incidence of monitor utilization was 36.5% (95% CI 31.7, 41.3), and 6-month mortality was 13.6% (10.4, 16.8). Monitoring was performed with Holter/event (n = 107; 72.3%), ILR (n = 34; 23.0%) or both (n = 7; 4.7%). Monitoring was more likely after cryptogenic (hazard ratio [HR] 4.53 [3.22, 6.39]; 6-month monitor incidence 70.6%) and cardioembolic (HR 2.43 [1.28, 4.62]; incidence 47.7%) stroke, versus other/undocumented (incidence 22.7%). Among patients with cryptogenic stroke, the 6-month incidence of ILR was 27.5% [18.5, 36.5]. Monitoring was more likely after discharge home (HR 1.80 [1.29, 2.52]; incidence 46.1%) versus facility (incidence 24.9%). Monitoring was not associated with CHARGE-AF score (HR 1.08 per 1-SD increase [0.91, 1.27]), even though CHARGE-AF was associated with incident AF (HR 1.56 [1.03, 2.35]). In conclusion, rhythm monitors are utilized after one-third of ischemic strokes. Monitoring is more frequent after cryptogenic strokes, though ILR use is low. Monitor utilization is not associated with AF risk.<br /> (Copyright © 2021 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1879-1913
Volume :
147
Database :
MEDLINE
Journal :
The American journal of cardiology
Publication Type :
Academic Journal
Accession number :
33617814
Full Text :
https://doi.org/10.1016/j.amjcard.2021.01.038