Back to Search Start Over

Physics of Particle Beam and Hypofractionated Beam Delivery in NSCLC.

Authors :
Paganetti H
Grassberger C
Sharp GC
Source :
Seminars in radiation oncology [Semin Radiat Oncol] 2021 Apr; Vol. 31 (2), pp. 162-169.
Publication Year :
2021

Abstract

The dosimetric advantages of particle therapy lead to significantly reduced integral dose to normal tissues, making it an attractive treatment option for body sites such as the thorax. With reduced normal tissue dose comes the potential for dose escalation, toxicity reduction, or hypofractionation. While proton and heavy ion therapy have been used extensively for NSCLC, there are challenges in planning and delivery compared with X-ray-based radiation therapy. Particularly, range uncertainties compounded by breathing motion have to be considered. This article summarizes the current state of particle therapy for NSCLC with a specific focus on the impact of dosimetric uncertainties in planning and delivery.<br /> (Copyright © 2020 Elsevier Inc. All rights reserved.)