Regional blood flows by the microsphere method: reproducibility in portal hypertensive rats and influence of a portal vein catheter.

Authors :
Hadengue A
Lee SS
Koshy A
Girod C
Lebrec D
Source :
Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine (New York, N.Y.) [Proc Soc Exp Biol Med] 1988 Apr; Vol. 187 (4), pp. 461-8.
Publication Year :
1988

Abstract

To determine the reproducibility of splanchnic blood flow measurements by the microsphere method in rats with portal hypertension and the effects of laparotomy with portal vein cannulation, eight groups of 10 rats were studied. Cardiac output and regional blood flows were measured twice, 10 min apart, in pentobarbital anesthetized or awake, sham-operated or portal vein-ligated rats, with or without portal cannulation. Variability between the two successive measurements was not affected by portal hypertension or portal cannulation, and was not different in the splanchnic territory and in other organs. Laparotomy with portal cannulation had no significant effect in sham-operated rats. In awake portal hypertensive rats, cardiac output (53.9 +/- 3.0 vs 45.8 +/- 2.9 ml.min-1.100 g body wt-1, P less than 0.01) and splanchnic blood flow (12.31 +/- 0.72 vs 9.34 +/- 0.85 ml.min-1.100 g body wt-1, P less than 0.01) were lower in portal vein cannulated rats compared with those of non-cannulated animals. In anesthetized portal hypertensive rats blood flows were unaffected by portal cannulation, but arterial pressure (100.2 +/- 4.3 vs 119.9 +/- 3.4 mm Hg, P less than 0.01) and heart rate (366.5 +/- 10.0 vs 405.5 +/- 7.4 beats.min-1, P less than 0.01) were elevated. Anesthesia also decreased portal pressure (14.8 +/- 0.5 vs 12.0 +/- 0.4 mm Hg, P less than 0.05) in portal hypertensive rats. We conclude that the microsphere method remains reproducible in portal hypertensive rat models. Laparotomy with portal cannulation can alter systemic and splanchnic hemodynamics in portal hypertensive rats; these effects can also be changed during pentobarbital anesthesia. Regional blood flow measurements in portal hypertensive rats should be performed in animals without portal cannulation and preferably in the awake state.

Details

Language :
English
ISSN :
0037-9727
Volume :
187
Issue :
4
Database :
MEDLINE
Journal :
Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine (New York, N.Y.)
Publication Type :
Academic Journal
Accession number :
3353395
Full Text :
https://doi.org/10.3181/00379727-187-42689