Back to Search
Start Over
Tailored Vessel-Catheter Diameter Ratio in a Direct Aspiration First-Pass Technique: Is It a Matter of Caliber?
- Source :
-
AJNR. American journal of neuroradiology [AJNR Am J Neuroradiol] 2021 Mar; Vol. 42 (3), pp. 546-550. Date of Electronic Publication: 2021 Jan 21. - Publication Year :
- 2021
-
Abstract
- Background and Purpose: The aspiration technique has gained a prominent role in mechanical thrombectomy. The thrombectomy goal is successful revascularization (modified TICI ≥ 2b) and first-pass effect. The purpose of this study was to evaluate the impact of the vessel-catheter ratio on the modified TICI ≥ 2b and first-pass effect.<br />Materials and Methods: This was a retrospective, single-center, cohort study. From January 2018 to April 2020, 111/206 (53.9%) were eligible after applying the exclusion criteria. Culprit vessel diameters were measured by 2 neuroradiologists, and the intraclass correlation coefficient was calculated. The receiver operating characteristic curve was used for assessing the vessel-catheter ratio cutoff for modified TICI ≥ 2b and the first-pass effect. Time to groin puncture and fibrinolysis were weighted using logistic regression. All possible intervals (interval size, 0.1; sliding interval, 0.01) of the vessel-catheter ratio were plotted, and the best and worst intervals were compared using the χ <superscript>2</superscript> test.<br />Results: Modified TICI ≥ 2b outcome was achieved in 75/111 (67.5%), and first-pass effect was achieved in 53/75 (70.6%). The MCA diameter was 2.1 mm with an intraclass correlation coefficient of 0.92. The optimal vessel-catheter ratio cutoffs for modified TICI ≥ 2b were ≤1.51 (accuracy = 0.67; 95% CI, 0.58-0.76; P = 0.001), and for first-pass effect, they were significant (≤1.33; P = .31). The modified TICI ≥ 2b odds ratio and relative risk were 9.2 (95% CI, 2.4-36.2; P = 0.002) and 3.2 (95% CI, 1.2-8.7; P = .024). The odds ratio remained significant after logistic regression (7.4; 95% CI, 1.7-32.5; P = .008). First-pass effect odds ratio and relative risk were not significant (2.1 and 1.5; P > .05, respectively). The modified TICI ≥ 2b best and worst vessel-catheter ratio intervals were not significantly different (55.6% versus 85.7%, P = .12). The first-pass effect best vessel-catheter ratio interval was significantly higher compared with the worst one (78.6% versus 40.0%, P = .03).<br />Conclusions: The aspiration catheter should be selected according to culprit vessel diameter. The optimal vessel-catheter ratio cutoffs were ≤1.51 for modified TICI ≥ 2b with an odds ratio of 9.2 and a relative risk of 3.2.<br /> (© 2021 by American Journal of Neuroradiology.)
Details
- Language :
- English
- ISSN :
- 1936-959X
- Volume :
- 42
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- AJNR. American journal of neuroradiology
- Publication Type :
- Academic Journal
- Accession number :
- 33478941
- Full Text :
- https://doi.org/10.3174/ajnr.A6987