Back to Search Start Over

[Assessment of setup errors of IGRT combined with a six degrees of freedom bed for patients with primary rectal cancer].

Authors :
Jiang SK
Wang JJ
Wang H
Zhou S
Yang RJ
Zhang RL
Lin L
Source :
Zhonghua zhong liu za zhi [Chinese journal of oncology] [Zhonghua Zhong Liu Za Zhi] 2021 Jan 23; Vol. 43 (1), pp. 155-159.
Publication Year :
2021

Abstract

Objective: To investigate the effect of six degree of freedom (6-DOF) bed combined with cone beam computed tomography (CBCT) in the on-line correction of setup errors in patients with primary rectal cancer. Methods: The clinicopathological data of 17 patients with primary rectal cancer in Department of Radiotherapy, Third Hospital of Peking University from July 2013 to January 2014 were collected. There were 14 males and 3 females, a median age of 65 years. The difference of CBCT and 6-DOF bed combined with CBCT online correction of patients with positioning error were retrospectively analyzed. Results: Before position correction, the first CBCT verification of setup errors in the three translation directions including X (left and right), Y (in and out) and Z (up and down) directions were (0.06±0.25) cm, (0.13±0.40) cm and (-0.28±0.31) cm, respectively. The setup errors of RX (rotation pitch), RY(rolling) and RZ (left and right rotation) directions were (0.62±1.15)°, (-0.19±0.99)°, and (-0.34 ± 0.84)°, respectively . After correction of IGRT combined with six freedom of bed, the setup errors of translation X, Y and Z were (0.01±0.09) cm, (-0.01±0.05) cm and (-0.03±0.08) cm, respectively, and the setup errors of rotation RX, RY and RZ directions were (-0.16±0.40)°, (0.36±0.31)°and (-0.01±0.25)°, respectively. There were significant differences in translation direction (X, Y and Z direction) and rotation direction (Rx, RY and RZ) before and after 6-DOF bed combined with CBCT correction (all P <0.05). In the translation direction, the higher frequency range of Z-direction error value was 0.20-0.79 cm. In the rotation direction, the frequency range of error in Rx direction was 0.20°-2.99°. There was no significant difference between bone mode and gray scale model registration ( P >0.05). With the progress of radiotherapy, the setup errors of X, Z, Rx, RY and RZ directions increased except Y direction. Conclusions: In radiotherapy, six freedom bed combined with CBCT is helpful to correct the setup errors of patients with primary rectal cancer. Six freedom bed may be used to correct the setup errors of patients with primary rectal cancer online. Image-guided radiation therapy (IGRT) is recommended for bone pattern registration in patients with rectal cancer.

Details

Language :
Chinese
ISSN :
0253-3766
Volume :
43
Issue :
1
Database :
MEDLINE
Journal :
Zhonghua zhong liu za zhi [Chinese journal of oncology]
Publication Type :
Academic Journal
Accession number :
33472330
Full Text :
https://doi.org/10.3760/cma.j.cn112152-20190130-00057