Back to Search Start Over

Graphene Oxide-Based Biocompatible 3D Mesh with a Tunable Porosity and Tensility for Cell Culture.

Authors :
Zhang Y
Liu X
Michelson K
Trivedi R
Wu X
Schepp E
Xing Y
Darland D
Zhao JX
Source :
ACS biomaterials science & engineering [ACS Biomater Sci Eng] 2018 May 14; Vol. 4 (5), pp. 1505-1517. Date of Electronic Publication: 2018 Mar 29.
Publication Year :
2018

Abstract

One of the major challenges associated with modeling the influence of the cellular microenvironment on cell growth and differentiation is finding suitable substrates for growing the cells in a manner that recapitulates the cell-cell and cell-microenvironmental interactions in vitro. As one approach to address this challenge, we have developed graphene oxide (GO)-3D mesh with tunable hardness and porosity for application in cell culture systems. The synthetic method of GO-3D mesh is simple, easily reproducible, and low cost. The foundation of the method is the combination of poly(ethylene)(glycol) (PEG) and GO together with a salt-leaching approach (NaCl) in addition to a controlled application of heat during the synthetic process to tailor the mechanical properties, porosity, and pore-size distribution of the resulting GO-3D mesh. With this methodology, the hydrogel formed by PEG and GO generates a microporous mesh in the presence of the NaCl, leading to the formation of a stable 3D scaffold after extensive heating and washing. Varying the ratio of NaCl to GO controls porosity, pore size, and pore connectivity for the GO-3D mesh. When the porosity is less than 90%, with an increasing ratio of NaCl to GO, the number of pores increases with good interconnectivity. The 3D-mesh showed excellent biocompatibility with vascular cells which can take on a morphology comparable to that observed in vessels in vivo. Cell proliferation and gene expression can be determined from cells grown on the GO-3D scaffold, providing a valuable tool for investigating cell-microenvironmental changes. The GO-3D mesh described results from the synergy of the combined chemical properties of the PEG and GO with the salt-leaching methodology to generate a unique and flexible mesh that can be modified and optimized for a variety of in vitro applications.

Details

Language :
English
ISSN :
2373-9878
Volume :
4
Issue :
5
Database :
MEDLINE
Journal :
ACS biomaterials science & engineering
Publication Type :
Academic Journal
Accession number :
33445308
Full Text :
https://doi.org/10.1021/acsbiomaterials.8b00190