Back to Search
Start Over
[Plan of the day adaptive radiotherapy for bladder cancer: Dosimetric and clinical results].
- Source :
-
Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique [Cancer Radiother] 2021 Jun; Vol. 25 (4), pp. 308-315. Date of Electronic Publication: 2021 Jan 06. - Publication Year :
- 2021
-
Abstract
- Purpose: To account of individual intra-pelvic anatomical variations in muscle invasive bladder cancer (MIBC) irradiation, adaptive radiotherapy (ART) using a personalized plan library may have dosimetric and clinical benefits.<br />Material and Methods: The data from ten patients treated for localized MIBC according to the "plan of the day" (P0oD) individualized ART technique were collected and retrospectively analysed. Target volumes and organs at risk (OAR) were delineated at different bladder fill rates, resulting in two or three treatment plans. Daily Cone-Beam CT (CBCT) was used for the selection of PoD at each fraction. Retrospectively, we delineated rectal, intestinal and target volumes on each CBCT, to assess target volume coverage and dose sparing to healthy tissues. A comparison with the conventional radiotherapy technique was performed. The secondary objectives were toxicity and efficacy.<br />Results: The target coverage was respected with the adaptive treatment: 97.3% for the bladder Clinical Target Volume (CTV) (99.5; [60.1-100]) and 98% for the bladder+lymph nodes CTV (98.6; [85.4-100]). Concerning OAR, the volume of healthy tissue spared was 43.7% on average and the V45Gy for the small bowel was 43,4cc (35; [0-129]) (versus 57,6cc). The rectal D50 was on average 18,7Gy for the adaptive treatment (15.9; [2.4-44.1]) versus 17Gy with the conventional approach. With a median follow-up of 2.94 years (95% CI: [0.92-4.02]), we observed three grade 3 toxicities (30%). No grade 4 toxicity was observed. The 2-year overall survival and progression-free survival rates were 65.6% (95% CI: [26-87.6]) and 45.7% (95% CI: [14.3-73]), respectively.<br />Conclusion: The ART technique using a PoD strategy showed a reduction of the irradiated healthy tissue volume while maintaining a similar bladder coverage, with an acceptable rate of toxicity.<br /> (Copyright © 2020 Société française de radiothérapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Cone-Beam Computed Tomography methods
Female
Humans
Intestine, Small diagnostic imaging
Male
Middle Aged
Neoplasm Recurrence, Local mortality
Organ Motion
Organ Sparing Treatments methods
Organs at Risk diagnostic imaging
Patient Positioning methods
Progression-Free Survival
Radiotherapy methods
Radiotherapy Dosage
Radiotherapy, Image-Guided methods
Rectum diagnostic imaging
Retrospective Studies
Urinary Bladder diagnostic imaging
Urinary Bladder Neoplasms diagnostic imaging
Urinary Bladder Neoplasms mortality
Urinary Bladder Neoplasms pathology
Radiotherapy Planning, Computer-Assisted methods
Urinary Bladder Neoplasms radiotherapy
Subjects
Details
- Language :
- French
- ISSN :
- 1769-6658
- Volume :
- 25
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique
- Publication Type :
- Academic Journal
- Accession number :
- 33422418
- Full Text :
- https://doi.org/10.1016/j.canrad.2020.10.002