Back to Search Start Over

Quantitative Evaluation of Subglottic Stenosis Using Ultrashort Echo Time MRI in a Rabbit Model.

Authors :
Gandhi DB
Rice A
Gunatilaka CC
Higano NS
Fleck RJ
de Alarcon A
Hart CK
Kuo IC
Amin RS
Woods JC
Hysinger EB
Bates AJ
Source :
The Laryngoscope [Laryngoscope] 2021 Jun; Vol. 131 (6), pp. E1971-E1979. Date of Electronic Publication: 2021 Jan 05.
Publication Year :
2021

Abstract

Objective/hypothesis: To assess the ability of ultra-short echo time (UTE)-MRI to detect subglottic stenosis (SGS) and evaluate response to balloon dilation. To correlate measurements from UTE-MRI with endotracheal-tube (ETT)-sizing and to investigate whether SGS causes change in airway dynamics.<br />Study Design: Animal research study.<br />Methods: Eight adult New-Zealand white rabbits were used as they approximate neonatal airway-size. The airways were measured using ETT-sizing and 3D UTE-MRI at baseline, 2 weeks post-cauterization induced SGS injury, and post-balloon dilation treatment. UTE-MR images were acquired to determine airway anatomy and motion. Airways were segmented from MR images. Cross-sectional area (CSA), major and minor diameters (D <subscript>major</subscript> and D <subscript>minor</subscript> ), and eccentricity were measured.<br />Results: Post-injury CSA at SGS was significantly reduced (mean 38%) compared to baseline (P = .003) using UTE-MRI. ETT-sizing correlated significantly with MRI-measured CSA at the SGS location (r = 0.6; P < .01), particularly at the post-injury timepoint (r = 0.93; P < .01). Outer diameter from ETT-sizing (OD) correlated significantly with D <subscript>major</subscript> (r = 0.63; P < .01) from UTE-MRI at the SGS location, especially for the post-injury timepoint (r = 0.91; P < .01). Mean CSA of upper trachea did not change significantly between end-expiration and end-inspiration at any timepoint (all P > .05). Eccentricity of the upper trachea increased significantly post-balloon dilation (P < .05).<br />Conclusions: UTE-MRI successfully detected SGS and treatment response in the rabbit model, with good correlation to ETT-sizing. Balloon dilation increased CSA at SGS, but not to baseline values. SGS did not alter dynamic motion for the trachea in this rabbit model; however, tracheas were significantly eccentric post-balloon dilation. UTE-MRI can detect SGS without sedation or ionizing radiation and may be a non-invasive alternative to ETT-sizing.<br />Level of Evidence: NA Laryngoscope, 131:E1971-E1979, 2021.<br /> (© 2021 The American Laryngological, Rhinological and Otological Society, Inc.)

Details

Language :
English
ISSN :
1531-4995
Volume :
131
Issue :
6
Database :
MEDLINE
Journal :
The Laryngoscope
Publication Type :
Academic Journal
Accession number :
33399240
Full Text :
https://doi.org/10.1002/lary.29363