Back to Search Start Over

Lean regional muscle volume estimates using explanatory bioelectrical models in healthy subjects and patients with muscle wasting.

Authors :
Bachasson D
Ayaz AC
Mosso J
Canal A
Boisserie JM
Araujo ECA
Benveniste O
Reyngoudt H
Marty B
Carlier PG
Hogrel JY
Source :
Journal of cachexia, sarcopenia and muscle [J Cachexia Sarcopenia Muscle] 2021 Feb; Vol. 12 (1), pp. 39-51. Date of Electronic Publication: 2020 Dec 29.
Publication Year :
2021

Abstract

Background: The availability of non-invasive, accessible, and reliable methods for estimating regional skeletal muscle volume is paramount in conditions involving primary and/or secondary muscle wasting. This work aimed at (i) optimizing serial bioelectrical impedance analysis (S <subscript>BIA</subscript> ) by computing a conductivity constant based on quantitative magnetic resonance imaging (MRI) data and (ii) investigating the potential of S <subscript>BIA</subscript> for estimating lean regional thigh muscle volume in patients with severe muscle disorders.<br />Methods: Twenty healthy participants with variable body mass index and 20 patients with idiopathic inflammatory myopathies underwent quantitative MRI. Anatomical images and fat fraction maps were acquired in thighs. After manual muscle segmentation, lean thigh muscle volume (lV <subscript>MRI</subscript> ) was computed. Subsequently, multifrequency (50 to 350 kHz) serial resistance profiles were acquired between current skin electrodes (i.e. ankle and hand) and voltage electrodes placed on the anterior thigh. In vivo values of the muscle electrical conductivity constant were computed using data from S <subscript>BIA</subscript> and MRI gathered in the right thigh of 10 healthy participants. Lean muscle volume (lV <subscript>BIA</subscript> ) was derived from S <subscript>BIA</subscript> measurements using this newly computed constant. Between-day reproducibility of lV <subscript>BIA</subscript> was studied in six healthy participants.<br />Results: Electrical conductivity constant values ranged from 0.82 S/m at 50 kHz to 1.16 S/m at 350 kHz. The absolute percentage difference between lV <subscript>BIA</subscript> and lV <subscript>MRI</subscript> was greater at frequencies >270 kHz (P < 0.0001). The standard error of measurement and the intra-class correlation coefficient for lV <subscript>BIA</subscript> computed from measurements performed at 155 kHz (i.e. frequency with minimal difference) against lV <subscript>MRI</subscript> were 6.1% and 0.95 in healthy participants and 9.4% and 0.93 in patients, respectively. Between-day reproducibility of lV <subscript>BIA</subscript> was as follows: standard error of measurement = 4.6% (95% confidence interval [3.2, 7.8] %), intra-class correlation coefficient = 0.98 (95% confidence interval [0.95, 0.99]).<br />Conclusions: These findings demonstrate a strong agreement of lean muscle volume estimated using S <subscript>BIA</subscript> against quantitative MRI in humans, including in patients with severe muscle wasting and fatty degeneration. S <subscript>BIA</subscript> shows promises for non-invasive, fast, and accessible estimation and follow-up of lean regional skeletal muscle volume for transversal and longitudinal studies.<br /> (© 2020 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of Society on Sarcopenia, Cachexia and Wasting Disorders.)

Details

Language :
English
ISSN :
2190-6009
Volume :
12
Issue :
1
Database :
MEDLINE
Journal :
Journal of cachexia, sarcopenia and muscle
Publication Type :
Academic Journal
Accession number :
33377299
Full Text :
https://doi.org/10.1002/jcsm.12656