Back to Search Start Over

Challenging handheld NIR spectrometers with moisture analysis in plant matrices: Performance of PLSR vs. GPR vs. ANN modelling.

Authors :
Mayr S
Beć KB
Grabska J
Wiedemair V
Pürgy V
Popp MA
Bonn GK
Huck CW
Source :
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy [Spectrochim Acta A Mol Biomol Spectrosc] 2021 Mar 15; Vol. 249, pp. 119342. Date of Electronic Publication: 2020 Dec 13.
Publication Year :
2021

Abstract

The global demand for natural products grows rapidly, intensifying the request for the development of high-throughput, fast, non-invasive tools for quality control applicable on-site. Moisture content is one of the most important quality parameters of natural products. It determines their market suitability, stability and shelf life and should preferably be constantly monitored. Miniaturized near-infrared (NIR) spectroscopy is a powerful method for on-site analysis, potentially fulfilling this requirement. Here, a feasibility study for applicability and analytical performance of three miniaturized NIR spectrometers and two benchtop instruments was evaluated in that scenario. The case study involved 192 dried plant extracts composed of five different plants harvested in different countries at various times within two years. The reference analysis by Karl Fischer titration determined the water content in this sample set between 1.36% and 6.47%. For the spectroscopic analysis half of the samples were laced with a drying agent to comply with the industry standard. The performance of various calibration models for NIR analysis was evaluated on the basis of root-mean square error of prediction (RMSEP) determined for an independent test set. Partial least squares regression (PLSR), Gaussian process regression (GPR) and artificial neural network (ANN) models were constructed for the spectral sets from each instrument. GPR and ANN models performed superior for all samples measured by handheld spectrometers and for native ones analyzed by benchtop instruments. Moreover, the accuracy penalty when analyzing native samples was lower for GPR and ANN prediction as well. With GPR or ANN calibration, miniaturized spectrometers offered the prediction performance at the level of the benchtop instruments. Therefore, in this analytical application miniaturized spectrometers can be used on-site with no penalty to the performance vs. laboratory-based NIR analysis.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2020 The Authors. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-3557
Volume :
249
Database :
MEDLINE
Journal :
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
Publication Type :
Academic Journal
Accession number :
33360568
Full Text :
https://doi.org/10.1016/j.saa.2020.119342