Back to Search
Start Over
A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion.
- Source :
-
The journal of extra-corporeal technology [J Extra Corpor Technol] 2020 Dec; Vol. 52 (4), pp. 303-313. - Publication Year :
- 2020
-
Abstract
- Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, p = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, p = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.<br /> (© Copyright 2020 AMSECT.)
Details
- Language :
- English
- ISSN :
- 0022-1058
- Volume :
- 52
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- The journal of extra-corporeal technology
- Publication Type :
- Academic Journal
- Accession number :
- 33343033
- Full Text :
- https://doi.org/10.1182/ject-2000034