Back to Search Start Over

Mechanical Vibration-Extracted Stromal Vascular Fraction Improves Volume Retention after Autologous Fat Grafting.

Authors :
Zhang K
Liu F
Zhang Y
Huang X
Tang M
Hou Y
Lv Q
Jin D
Li Y
Kong L
Source :
Plastic and reconstructive surgery [Plast Reconstr Surg] 2020 Dec; Vol. 146 (6), pp. 1275-1284.
Publication Year :
2020

Abstract

Background: The stromal vascular fraction can improve volume retention after fat grafting, but the optimal stromal vascular fraction extraction method remains controversial. This study investigated the effect of mechanical vibration on stromal vascular fraction activity and explored the efficacy of vibration as a new extraction method compared to centrifugation, enzyme digestion, and nanoemulsion methods.<br />Methods: Twenty-four rabbits were divided into three groups, and adipose tissue was harvested from the scapular region of each rabbit. In the first group, stromal vascular fraction was extracted from adipose tissue by vibration with different frequencies and durations. Cell counts and colony formation were assessed to determine the optimal vibration parameters. In the second group, stromal vascular fraction was extracted by the four methods, and the cell counts, proliferation, and adipogenic capabilities were observed in vitro. In the third group, adipose tissue mixed with stromal vascular fraction extracted by means of the four methods was grafted into rabbit ears. Volume retention and histologic changes were evaluated over 24 weeks.<br />Results: Stromal vascular fraction activity was not influenced by low-frequency (≤45 Hz) and short-duration (≤20 minutes) vibrations. Vibration at 30 Hz for 15 minutes was most efficient for stromal vascular fraction extraction. In vitro, stromal vascular fraction extracted by vibration showed advantages for cell viability. In vivo, the vibration group showed a more normal tissue morphology and a higher retention rate (60.68 ± 7.07 percent) than the enzyme digestion (31.88 ± 4.99 percent), centrifugation (43.76 ± 4.32 percent), and nanoemulsion groups (21.79 ± 3.57 percent) (p < 0.05).<br />Conclusion: Vibration at 30 Hz for 15 minutes is recommended as a novel nonenzymatic method to extract stromal vascular fraction with high activity.

Details

Language :
English
ISSN :
1529-4242
Volume :
146
Issue :
6
Database :
MEDLINE
Journal :
Plastic and reconstructive surgery
Publication Type :
Academic Journal
Accession number :
33234957
Full Text :
https://doi.org/10.1097/PRS.0000000000007341