Back to Search Start Over

Inter-individual variability in atrasentan exposure partly explains variability in kidney protection and fluid retention responses: A post hoc analysis of the SONAR trial.

Authors :
Koomen JV
Stevens J
Bakris G
Correa-Rotter R
Hou FF
Kitzman DW
Kohan D
Makino H
McMurray JJV
Parving HH
Perkovic V
Tobe SW
de Zeeuw D
Heerspink HJL
Source :
Diabetes, obesity & metabolism [Diabetes Obes Metab] 2021 Feb; Vol. 23 (2), pp. 561-568. Date of Electronic Publication: 2020 Nov 26.
Publication Year :
2021

Abstract

Aim: To evaluate whether atrasentan plasma exposure explains between-patient variability in urinary albumin-to-creatinine ratio (UACR) response, a surrogate for kidney protection, and B-type natriuretic peptide (BNP) response, a surrogate for fluid expansion.<br />Methods: Type 2 diabetic patients with chronic kidney disease (n = 4775) received 0.75 mg atrasentan for 6 weeks in the active run-in period. Individual area under the concentration-time-curve (AUC) was estimated using a population pharmacokinetic model. The association between atrasentan AUC, other clinical characteristics, and UACR and BNP response, was estimated using linear regression.<br />Results: The median atrasentan AUC was 43.8 ng.h/mL with a large variation among patients (2.5th-97.5th percentiles [P]: 12.6 to 197.5 ng.h/mL). Median UACR change at the end of enrichment was -36.0% and median BNP change was 8.7%, which also varied among patients (UACR, 2.5th-97.5th P: -76.2% to 44.5%; BNP, 2.5th-97.5th P: -71.5% to 300.0%). In the multivariable analysis, higher atrasentan AUC was associated with greater UACR reduction (4.88% per doubling in ng.h/mL [95% confidence interval {CI}: 6.21% to 3.52%], P < .01) and greater BNP increase (3.08% per doubling in ng.h/mL [95% CI: 1.12% to 4.11%], P < .01) independent of estimated glomerular filtration rate, haemoglobin or BNP. Caucasian patients compared with black patients had greater UACR reduction (7.06% [95% CI: 1.38% to 13.07%]) and also greater BNP increase (8.75% [95% CI: 1.65% to 15.35%]). UACR response was not associated with BNP response (r = 0.06).<br />Conclusion: Atrasentan plasma exposure varied among individual patients and partially explained between-patient variability in efficacy and safety response.<br /> (© 2020 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1463-1326
Volume :
23
Issue :
2
Database :
MEDLINE
Journal :
Diabetes, obesity & metabolism
Publication Type :
Academic Journal
Accession number :
33184931
Full Text :
https://doi.org/10.1111/dom.14252