Back to Search Start Over

Biomechanical and histomorphometric analysis of endosteal implants placed by using the osseodensification technique in animal models: A systematic review and meta-analysis.

Authors :
Gaikwad AM
Joshi AA
Nadgere JB
Source :
The Journal of prosthetic dentistry [J Prosthet Dent] 2022 Jan; Vol. 127 (1), pp. 61-70. Date of Electronic Publication: 2020 Oct 31.
Publication Year :
2022

Abstract

Statement of Problem: Osseodensification, a counterclockwise drilling technique for the placement of endosseous implants is a popular clinical technique. However, the effect of the osseodensification technique on primary implant stability, bone-implant contact, and bone area frequency occupancy is unclear.<br />Purpose: The purpose of this systematic review and meta-analysis was to investigate the biomechanical and histomorphometric outcomes of endosteal implants placed by using the osseodensification technique in animal models.<br />Material and Methods: An electronic search through Medline/PubMed, Lilacs, and Science Direct databases, and an additional manual search of the reference list of included articles was conducted by using specific keywords and Medical Subject Headings (MeSH) terms for articles in the English language and published up to April 31, 2020. Only animal studies comparing the biomechanical and histomorphometric outcomes of endosteal implants placed by using the osseodensification and conventional drilling protocol were included. The SYstematic Review Center for Laboratory animal Experimentation (SYRCLE) tool was used to determine the risk of bias assessment, and the quality of included studies was assessed by using Animal Research: Reporting in Vivo Experiments (ARRIVE) guidelines.<br />Results: Nine studies were included. The results of the meta-analysis showed that the pooled weighted mean difference of the insertion torque value for the primary implant stability of endosseous dental implants placed by using the osseodensification technique was 2.270 (95% confidence interval [CI]=1.147 to 3.393; P<.001), the weighted mean difference of the percentage of bone-implant contact at 3 weeks was 0.487 (95% CI=0.220 to 0.754; P=.114), the weighted mean difference of the percentage of bone-implant contact at 6 weeks was 0.565 (95% CI=0.219 to 0.911; P=.448), the weighted mean difference of the percentage of bone area frequency occupancy at 3 weeks was 0.679 (95% CI=0.265 to 1.093; P=.073), and the weighted mean difference of the percentage of bone area frequency occupancy at 6 weeks was 0.391 (95% CI=-0.204 to 0.986; P=.027).<br />Conclusions: Limited data from animal studies suggest that the primary implant stability, bone-implant contact, and bone area frequency occupancy significantly improved for the endosteal implants placed by using the osseodensification technique compared with conventional drilling protocol. However, additional laboratory and clinical studies are recommended to provide stronger evidence.<br /> (Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1097-6841
Volume :
127
Issue :
1
Database :
MEDLINE
Journal :
The Journal of prosthetic dentistry
Publication Type :
Academic Journal
Accession number :
33139057
Full Text :
https://doi.org/10.1016/j.prosdent.2020.07.004