Back to Search Start Over

Automated Segmentation of Retinal Fluid Volumes From Structural and Angiographic Optical Coherence Tomography Using Deep Learning.

Authors :
Guo Y
Hormel TT
Xiong H
Wang J
Hwang TS
Jia Y
Source :
Translational vision science & technology [Transl Vis Sci Technol] 2020 Oct 08; Vol. 9 (2), pp. 54. Date of Electronic Publication: 2020 Oct 08 (Print Publication: 2020).
Publication Year :
2020

Abstract

Purpose: We proposed a deep convolutional neural network (CNN), named Retinal Fluid Segmentation Network (ReF-Net), to segment retinal fluid in diabetic macular edema (DME) in optical coherence tomography (OCT) volumes.<br />Methods: The 3- × 3-mm OCT scans were acquired on one eye by a 70-kHz OCT commercial AngioVue system (RTVue-XR; Optovue, Inc., Fremont, CA, USA) from 51 participants in a clinical diabetic retinopathy (DR) study (45 with retinal edema and six healthy controls, age 61.3 ± 10.1 (mean ± SD), 33% female, and all DR cases were diagnosed as severe NPDR or PDR). A CNN with U-Net-like architecture was constructed to detect and segment the retinal fluid. Cross-sectional OCT and angiography (OCTA) scans were used for training and testing ReF-Net. The effect of including OCTA data for retinal fluid segmentation was investigated in this study. Volumetric retinal fluid can be constructed using the output of ReF-Net. Area-under-receiver-operating-characteristic-curve, intersection-over-union (IoU), and F1-score were calculated to evaluate the performance of ReF-Net.<br />Results: ReF-Net shows high accuracy (F1 = 0.864 ± 0.084) in retinal fluid segmentation. The performance can be further improved (F1 = 0.892 ± 0.038) by including information from both OCTA and structural OCT. ReF-Net also shows strong robustness to shadow artifacts. Volumetric retinal fluid can provide more comprehensive information than the two-dimensional (2D) area, whether cross-sectional or en face projections.<br />Conclusions: A deep-learning-based method can accurately segment retinal fluid volumetrically on OCT/OCTA scans with strong robustness to shadow artifacts. OCTA data can improve retinal fluid segmentation. Volumetric representations of retinal fluid are superior to 2D projections.<br />Translational Relevance: Using a deep learning method to segment retinal fluid volumetrically has the potential to improve the diagnostic accuracy of diabetic macular edema by OCT systems.<br />Competing Interests: Disclosure: Y. Guo, None; T.T. Hormel, None; H. Xiong, None; J. Wang, None; T.S. Hwang, None; Y. Jia, Optovue (F, P)<br /> (Copyright 2020 The Authors.)

Details

Language :
English
ISSN :
2164-2591
Volume :
9
Issue :
2
Database :
MEDLINE
Journal :
Translational vision science & technology
Publication Type :
Academic Journal
Accession number :
33110708
Full Text :
https://doi.org/10.1167/tvst.9.2.54