Back to Search Start Over

Improved Detection of Scaphoid Fractures with High-Resolution Peripheral Quantitative CT Compared with Conventional CT.

Authors :
Daniels AM
Bevers MSAM
Sassen S
Wyers CE
van Rietbergen B
Geusens PPMM
Kaarsemaker S
Hannemann PFW
Poeze M
van den Bergh JP
Janzing HMJ
Source :
The Journal of bone and joint surgery. American volume [J Bone Joint Surg Am] 2020 Dec 16; Vol. 102 (24), pp. 2138-2145.
Publication Year :
2020

Abstract

Background: Computed tomography (CT), magnetic resonance imaging, and bone scintigraphy are second-line imaging techniques that are frequently used for the evaluation of patients with a clinically suspected scaphoid fracture. However, as a result of varying diagnostic performance results, no true reference standard exists for scaphoid fracture diagnosis. We hypothesized that the use of high-resolution peripheral quantitative CT (HR-pQCT) in patients with a clinically suspected scaphoid fracture could improve scaphoid fracture detection compared with conventional CT in the clinical setting.<br />Methods: The present study included 91 consecutive patients (≥18 years of age) who presented to the emergency department with a clinically suspected scaphoid fracture between December 2017 and October 2018. All patients were clinically reassessed within 14 days after first presentation, followed by CT and HR-pQCT. If a scaphoid fracture was present, the fracture type was determined according to the Herbert classification system and correlation between CT and HR-pQCT was estimated with use of the Kendall W statistic or coefficient of concordance (W) (the closer to 1, the higher the correlation).<br />Results: The cohort included 45 men and 46 women with a median age of 52 years (interquartile range, 29 to 67 years). HR-pQCT revealed a scaphoid fracture in 24 patients (26%), whereas CT revealed a scaphoid fracture in 15 patients (16%). Patients with a scaphoid fracture were younger and more often male. The correlation between CT and HR-pQCT was high for scaphoid fracture type according to the Herbert classification system (W = 0.793; 95% confidence interval [CI], 0.57 to 0.91; p < 0.001) and very high for scaphoid fracture location (W = 0.955; 95%, CI 0.90 to 0.98; p < 0.001).<br />Conclusions: In the present study, the number of patients diagnosed with a scaphoid fracture was 60% higher when using HR-pQCT as compared with CT. These findings imply that a substantial proportion of fractures-in this study, more than one-third-will be missed by the current application of CT scanning in patients with a clinically suspected scaphoid fracture.<br />Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.<br />Competing Interests: Disclosure: The authors indicated that no external funding was received for any aspect of this work. On the Disclosure of Potential Conflicts of Interest forms, which are provided with the online version of the article, one or more of the authors checked “yes” to indicate that the author had a relevant financial relationship in the biomedical arena outside the submitted work (http://links.lww.com/JBJS/G169).<br /> (Copyright © 2020 by The Journal of Bone and Joint Surgery, Incorporated.)

Details

Language :
English
ISSN :
1535-1386
Volume :
102
Issue :
24
Database :
MEDLINE
Journal :
The Journal of bone and joint surgery. American volume
Publication Type :
Academic Journal
Accession number :
33079896
Full Text :
https://doi.org/10.2106/JBJS.20.00124