Back to Search Start Over

Development and validation of an age-scalable cardiac model with substructures for dosimetry in late-effects studies of childhood cancer survivors.

Authors :
Shrestha S
Gupta AC
Bates JE
Lee C
Owens CA
Hoppe BS
Constine LS
Smith SA
Qiao Y
Weathers RE
Yasui Y
Court LE
Paulino AC
Pinnix CC
Kry SF
Followill DS
Armstrong GT
Howell RM
Source :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology [Radiother Oncol] 2020 Dec; Vol. 153, pp. 163-171. Date of Electronic Publication: 2020 Oct 17.
Publication Year :
2020

Abstract

Background and Purpose: Radiation therapy is a risk factor for late cardiac disease in childhood cancer survivors. Several pediatric cohort studies have established whole heart dose and dose-volume response models. Emerging data suggest that dose to cardiac substructures may be more predictive than whole heart metrics. In order to develop substructure dose-response models, the heart model previously used for pediatric cohort dosimetry needed enhancement and substructure delineation.<br />Methods: To enhance our heart model, we combined the age-scalable capability of our computational phantom with the anatomically-delineated (with substructures) heart models from an international humanoid phantom series. We examined cardiac volume similarity/overlap between registered age-scaled phantoms (1, 5, 10, and 15 years) with the enhanced heart model and the reference phantoms of the same age; dice similarity coefficient (DSC) and overlap coefficient (OC) were calculated for each matched pair. To assess the accuracy of our enhanced heart model, we compared doses from computed tomography-based planning (ground truth) with reconstructed heart doses. We also compared doses calculated with the prior and enhanced heart models for a cohort of nearly 5000 childhood cancer survivors.<br />Results: We developed a realistic cardiac model with 14-substructures, scalable across a broad age range (1-15 years); average DSC and OC were 0.84 ± 0.05 and 0.90 ± 0.05, respectively. The average percent difference between reconstructed and ground truth mean heart doses was 4.2%. In the cohort dosimetry analysis, dose and dose-volume metrics were approximately 10% lower on average when the enhanced heart model was used for dose reconstructions.<br />Conclusion: We successfully developed and validated an anatomically realistic age-scalable cardiac model that can be used to establish substructure dose-response models for late cardiac disease in childhood cancer survivor cohorts.<br /> (Copyright © 2020 The Author(s). Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1879-0887
Volume :
153
Database :
MEDLINE
Journal :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
Publication Type :
Academic Journal
Accession number :
33075392
Full Text :
https://doi.org/10.1016/j.radonc.2020.10.017