Back to Search Start Over

Diagnostic Accuracy of Microultrasound in Patients with a Suspicion of Prostate Cancer at Magnetic Resonance Imaging: A Single-institutional Prospective Study.

Authors :
Lughezzani G
Maffei D
Saita A
Paciotti M
Diana P
Buffi NM
Colombo P
Elefante GM
Hurle R
Lazzeri M
Guazzoni G
Casale P
Source :
European urology focus [Eur Urol Focus] 2021 Sep; Vol. 7 (5), pp. 1019-1026. Date of Electronic Publication: 2020 Oct 15.
Publication Year :
2021

Abstract

Background: Multiparametric magnetic resonance imaging (MRI) represents the gold standard for the diagnosis of clinically significant prostate cancer (csPCa). The search for alternative diagnostic techniques is still ongoing.<br />Objective: To determine the accuracy of microultrasound (microUS) for the diagnosis of csPCa within prospectively collected cohort of patients with a suspicion of prostate cancer (PCa) according to MRI.<br />Design, Setting, and Participants: A total of 320 consecutive patients with at least one Prostate Imaging Reporting and Data System (PIRADS) ≥3 lesion according to MRI were prospectively enrolled.<br />Intervention: All patients received microUS before prostate biopsy using the ExactVu system; the Prostate Risk Identification using microUS (PRI-MUS) protocol was used to identify targets. The urologists were blinded to MRI results until after the microUS targeting was completed. All patients received both targeted (based on either microUS or MRI findings) and randomized biopsies.<br />Outcome Measurements and Statistical Analysis: The sensitivity and specificity of microUS to determine the presence of csPCa (defined as at least one core with a Gleason score ≥7 PCa) were determined. Multivariable logistic regression analysis was fitted to determine the predictors of csPCa.<br />Results and Limitations: Clinically significant PCa was diagnosed in 116 (36.3%) patients. The sensitivity and negative predictive value of microUS for csPCa diagnosis were 89.7% and 81.5%, while specificity and positive predictive value were 26.0% and 40.8%, respectively. A combination of microUS-targeted and randomized biopsies would allow diagnosing the same proportion of csPCa as that diagnosed by an approach combining MRI-targeted and randomized biopsies (n = 113; 97.4%), with only three (2.6%) csPCa cases diagnosed by a microUS-targeted and three (2.6%) by an MRI-targeted approach. In a logistic regression model, an increasing PRI-MUS score was an independent predictor of csPCa (p ≤ 0.005). The main limitation of the current study is represented by the fact that all patients had suspicious MRI.<br />Conclusions: Microultrasound is a promising imaging modality for targeted prostate biopsies. Our results suggest that a microUS-based biopsy strategy may be capable of diagnosing the great majority of cancers, while missing only few patients with csPCa.<br />Patient Summary: According to our results, microultrasound (microUS) may represent an effective diagnostic alternative to magnetic resonance imaging for the diagnosis of clinically significant prostate cancer, providing high sensitivity and a high negative predictive value. Further randomized studies are needed to confirm the potential role of microUS in the diagnostic pathway of patients with a suspicion of prostate cancer.<br /> (Copyright © 2020 European Association of Urology. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
2405-4569
Volume :
7
Issue :
5
Database :
MEDLINE
Journal :
European urology focus
Publication Type :
Academic Journal
Accession number :
33069624
Full Text :
https://doi.org/10.1016/j.euf.2020.09.013