Back to Search Start Over

The effect of bovine serum albumin-glutaraldehyde and polyethylene glycol polymer on neointimal hyperplasia in rabbit carotid artery anastomosis.

Authors :
Karaagac E
Besir Y
Kurus M
Gokalp O
Iscan S
Gokkurt Y
Kandemir C
Topal FE
Keselik E
Eygi B
Gurbuz A
Source :
Journal of biomaterials applications [J Biomater Appl] 2021 Jul; Vol. 36 (1), pp. 152-164. Date of Electronic Publication: 2020 Oct 13.
Publication Year :
2021

Abstract

Objective: Since the systemic drugs have been used to reduce the hyperplasic response in the tunica intima, the periadventitial local drug applications to the vascular wall have gained more popularity. In this study, we investigated the effect of bovine serum albumin-glutaraldehyde and polyethylene glycol polymer on neointimal hyperplasia in rabbit carotid artery anastomosis to explore the effects of these two different agents.<br />Methods: 21 New Zealand male rabbits were randomly divided into three groups. The carotid artery transection and anastomosis was performed onthe control group. The bovine serum albumin-glutaraldehyde and the polyethylene glycol polymer were applied locally on the other two groups seperatley after transection and anastomosis of the carotid arteries. At the end of 28-day follow-up, the histological and the immunohistochemical results related to neointimal hyperplasia were compared.<br />Results: The glue residues were detected in the BSA-glutaraldehyde group, but in the PEG polymer group there was no glue residue. The intima thickness and the intima/media thickness ratio in the control group was significantly higher (p<0.05) than the other groups. These values did not differ significantly between the BSA-glutaraldehyde group and the PEG polymer group (p>0.05). The lumen diameter and the area in the control group were significantly higher (p < 0.05) than the BSA-glutaraldehyde group. These values between the control group and the PEG polymer group did not differ significantly (p>0.05). aSMA-positive staining score in the Control group was found to be significantly lower (p < 0.05) than the BSA-glutaraldehyde and PEG polymer group and the VEGF-positive staining score in the control group was found to be significantly higher (p < 0.05) than the BSA-glutaraldehyde and the PEG polymer group.<br />Conclusions: Although the both agents have positive results on neointimal hyperplasia, it would be favorable to use polyethylene glycol polymer, since it does not seem to affect the lumen area and the lumen diameter of the vessel.

Details

Language :
English
ISSN :
1530-8022
Volume :
36
Issue :
1
Database :
MEDLINE
Journal :
Journal of biomaterials applications
Publication Type :
Academic Journal
Accession number :
33050834
Full Text :
https://doi.org/10.1177/0885328220964913