Back to Search Start Over

Brazilian Translation, Cross-Cultural Adaptation, Validity, and Reliability of the EMpowerment of PArents in THe Intensive Care 30 (EMPATHIC-30) Questionnaire to Measure Parental Satisfaction in PICUs.

Authors :
Lessa AD
Cabral FC
Tonial CT
Costa CAD
Andrades GRH
Crestani F
Einloft PR
Bruno F
Sganzerla D
Matte MCC
Fiori HH
Latour JM
Garcia PCR
Source :
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies [Pediatr Crit Care Med] 2021 Jun 01; Vol. 22 (6), pp. e339-e348.
Publication Year :
2021

Abstract

Objectives: To conduct the Brazilian translation, cross-cultural adaptation, validation, and reliability testing of the EMpowerment of PArents in THe Intensive Care (EMPATHIC-30).<br />Design: Prospective study.<br />Setting: PICU of a tertiary-care teaching hospital.<br />Patients: Parents (n = 141) completed the translated EMPATHIC-30 questionnaire 72 hours after their child's PICU discharge.<br />Interventions: None.<br />Measurements and Main Results: The translation and cultural adaptation were performed in accordance with the principles of good practice for the translation and cultural adaptation process for patient-reported outcomes measures. Sentences were adapted according to the Brazilian syntax. Total content validity coefficient was above the established average (> 0.8). Reliability was evaluated with the coefficients McDonald omega and Cronbach alpha. The lowest Cronbach alpha found was 0.47 (CI 95%, 0.35-0.59) in the organization domain, where the lowest response rate was also concentrated. The values of the other domains were as follows: 0.64 (95% CI, 0.55-0.73) for information, 0.77 (95% CI, 0.71-0.83) for care and treatment, 0.72 (95% CI, 0.66-0.78) for parent participation, and 0.72 (95% CI, 0.65-0.79) for professional attitudes. The total internal consistency independent of the domain was 0.90 (CI 95%, 0.88-0.92). With regard to McDonald Omega, values were identified: 0.68 (95% CI, 0.49-0.88) for information, 0.73 (95% CI, 0.61-0.85) for care and treatment, 0.85 (95% CI, 0.47-0.80) for parent participation, 0.85 (95% CI, 0.76-0.93), and 0.72 (95% CI, 0.58-0.86) for professional attitudes.<br />Conclusions: EMPATHIC-30 has been translated and culturally adapted for the Brazilian population. Validation demonstrated an above-average total content validity coefficient, confirming the instrument content validity. A sufficient reliability was observed in both analyzed coefficients. The results support the use of the Brazilian version of EMPATHIC-30 for the evaluation of parents' satisfaction of children admitted to the PICU.<br />Competing Interests: Dr. Garcia received Scientific Productivity Grants from the Brazilian National Council for Scientific and Technological Development. The remaining authors have disclosed that they do not have any potential conflicts of interest.<br /> (Copyright © 2020 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.)

Details

Language :
English
ISSN :
1529-7535
Volume :
22
Issue :
6
Database :
MEDLINE
Journal :
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
Publication Type :
Academic Journal
Accession number :
33044413
Full Text :
https://doi.org/10.1097/PCC.0000000000002594