Back to Search Start Over

Evaluation of phenotypic tests for detection of carbapenemases: New modifications with new interpretation.

Authors :
Gelmez GA
Can B
Hasdemir U
Soyletir G
Source :
Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy [J Infect Chemother] 2021 Feb; Vol. 27 (2), pp. 226-231. Date of Electronic Publication: 2020 Sep 29.
Publication Year :
2021

Abstract

Introduction: The emergence and spread of carbapenemase-producing Enterobacterales (CPE) is a worldwide public health threat. Rapid and accurate detection of CPE is essential to prevent their dissemination within health care settings. The aim of this study was to evaluate the performance of CIM, mCIM and mCIM with ammonium bicarbonate (mCIM-A) methods by using different interpretation criteria for detection of carbapenemases.<br />Methods: One hundred and fifty-three Klebsiella pneumoniae isolates previously characterized by molecular tests, including 133 carbapenemase producers and 20 non-carbapenemase producers, were collected in this study. CIM and mCIM tests were performed as described previously. mCIM-A by adding 50 mM ammonium bicarbonate to the bacterial suspension prepared in tryptic soy broth. The inhibition zone diameter of around meropenem disc was measured and interpreted as positive according to i) Pierce and colleagues (<19 mm), ii) EUCAST meropenem susceptibility breakpoint (<22).<br />Results: CIM, although seems to be good for carbapenemases other than OXA-48-like and NDM, is not satisfactory (42.3% and 83.4%, respectively) for those enzymes with any of the interpretation criteria. OXA-48-like and NDM were detected with a better performance (88.7% and 92.8, respectively) with mCIM when results were interpreted according to <22 mm zone diameter for OXA-48-like and NDM. The best results were obtained with mCIM-A using <22 mm criteria without any difference in the results of other enzymes and negative strains.<br />Conclusions: mCIM-A method interpreted with <22 mm meropenem zone diameter seems to be preferable compared to CIM and mCIM. mCIM-A is simple and useful tool for identification of CPEs in clinical microbiology laboratories.<br />Competing Interests: Declaration of competing interest The authors declare that they have no conflict of interest.<br /> (Copyright © 2020 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1437-7780
Volume :
27
Issue :
2
Database :
MEDLINE
Journal :
Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy
Publication Type :
Academic Journal
Accession number :
33008736
Full Text :
https://doi.org/10.1016/j.jiac.2020.09.021