Back to Search Start Over

Increased contact area of flange and decreased wedge volume of osteotomy site by open wedge distal tibial tuberosity arc osteotomy compared to the conventional technique.

Authors :
Nejima S
Kumagai K
Fujimaki H
Yamada S
Sotozawa M
Matsubara J
Inaba Y
Source :
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA [Knee Surg Sports Traumatol Arthrosc] 2021 Oct; Vol. 29 (10), pp. 3450-3457. Date of Electronic Publication: 2020 Sep 28.
Publication Year :
2021

Abstract

Purpose: The purpose of this study was to evaluate the area of the osteotomy surface, including the flange and wedge volume, in open wedge high tibial osteotomy (OWHTO), distal tibial tuberosity osteotomy (DTO), and distal tibial tuberosity arc osteotomy (DTAO) using tibial sawbones. It was hypothesized that the area of the osteotomy surface, including the flange, in DTAO was larger than that in OWHTO and DTO and that the wedge volume in DTAO was smaller than that in OWHTO and DTO.<br />Methods: Fifteen tibial sawbones were divided equally into three groups: OWHTO, DTO, and DTAO. The total area of the osteotomy surface in OWHTO, DTO, and DTAO was compared using image analysis software. The contact area of the flange and the wedge volume at wedge heights of 5, 10, and 15 mm were compared among osteotomy types. One-way repeated-measures analysis of variance was used to compare the total area of the osteotomy surface, the contact area of the flange, and the wedge volume at 5, 10, and 15 mm in OWHTO, DTO, and DTAO.<br />Results: The total area of the osteotomy surface in DTO and DTAO was significantly larger than that in OWHTO (P < 0.05). The contact area of the flange in DTAO was significantly larger than that in OWHTO at each wedge height (P < 0.05). In addition, the contact area of the flange in DTAO was significantly larger than that in DTO at wedge heights of 5 and 15 mm (P < 0.05). The wedge volume in DTAO was significantly smaller than that in DTO at each wedge height (P < 0.05).<br />Conclusions: This study demonstrated that an increase in the flange contact area and a decrease in the wedge volume in the opening gap were found in DTAO compared to DTO. This would be an advantage for anteroposterior screw insertion from the flange to the distal tibial fragment and bone union at the osteotomy site.<br /> (© 2020. European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA).)

Details

Language :
English
ISSN :
1433-7347
Volume :
29
Issue :
10
Database :
MEDLINE
Journal :
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA
Publication Type :
Academic Journal
Accession number :
32986149
Full Text :
https://doi.org/10.1007/s00167-020-06296-8