Temporary Implant-Supported Single Crowns Using Titanium Base Abutments: An In Vitro Study on Bonding Stability and Pull-out Forces.
- Source :
-
The International journal of prosthodontics [Int J Prosthodont] 2020 Sep/Oct; Vol. 33 (5), pp. 546-552. - Publication Year :
- 2020
-
Abstract
- Purpose: To evaluate the effect of cementation protocols on the bonding interface stability and pull-out forces of temporary implant-supported crowns bonded on a titanium base abutment (TiB) or on a temporary titanium abutment (TiA).<br />Materials and Methods: A total of 60 implants were restored with PMMA-based CAD/CAM crowns. Five groups (n = 12) were created: Group 1 = TiB/SRc: crown conditioned with MMA-based liquid (SR Connect, Ivoclar Vivadent); Group 2 = TiB/50Al-MB: crown airborne particle-abraded with 50-μm Al <subscript>2</subscript> O <subscript>3</subscript> and silanized (Monobond Plus, Ivoclar Vivadent); Group 3 = TiB/30SiOAl-SRc: crown airborne particle-abraded with 30-μm silica-coated Al <subscript>2</subscript> O <subscript>3</subscript> (CoJet, 3M ESPE) and conditioned with MMA-based liquid (SR Connect); Group 4 = TiB/30SiOAl-MB: crown airborne particle-abraded with 30- μm silica-coated Al <subscript>2</subscript> O <subscript>3</subscript> (CoJet) and silanized (Monobond Plus); and Group 5 = TiA/TA-PMMA: crown manually enlarged, activated, and rebased with PMMA resin (Telio Lab, Ivoclar Vivadent). Specimens in the TiB groups were cemented using a resin cement (Multilink Hybrid Abutment, Ivoclar Vivadent). After aging (120,000 cycles, 49 N, 1.67 Hz, 5°C to 55°C, 120 seconds), bonding interface failure was analyzed (50x). Pull-out forces (N) (0.5 mm/minute) and modes of failure were registered. Chi-square and Kruskal-Wallis tests were used to analyze the data (α = .05).<br />Results: Bonding failure after aging varied from 0% (Group 5) to 100% (Groups 1, 2, and 4) (P < .001). Mean pull-out force ranged between 53.1 N (Group 1) and 1,146.5 N (Group 5). The pull-off forces were significantly greater for Group 5 (P < .05), followed by Group 3 (P < .05), whereas the differences among the remaining groups were not significant (P > .05).<br />Conclusion: The cementation protocol had an effect on the bonding interface stability and pull-out forces of PMMA-based crowns bonded on a titanium base. Airborne particle abrasion of the crown internal surface and conditioning it with an MMA-based liquid may be recommended to improve retention of titanium base temporary restorations. Yet, for optimal outcomes, conventional temporary abutments might be preferred.
Details
- Language :
- English
- ISSN :
- 1942-4426
- Volume :
- 33
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- The International journal of prosthodontics
- Publication Type :
- Academic Journal
- Accession number :
- 32956436
- Full Text :
- https://doi.org/10.11607/ijp.6778