Back to Search Start Over

Ceramic Liner Fracture Caused by an Impingement between the Stem Shoulder and the Ceramic Liner.

Authors :
Lee S
Jeon SW
Yoo JJ
Kim HJ
Source :
Hip & pelvis [Hip Pelvis] 2020 Sep; Vol. 32 (3), pp. 156-160. Date of Electronic Publication: 2020 Sep 02.
Publication Year :
2020

Abstract

Mechanisms of ceramic liner fractures have not yet been fully elucidated. Impingement between a stem and ceramic liner is a proposed cause of ceramic liner fractures. We experienced a case of ceramic liner fracture caused by direct impingement between the stem shoulder and the ceramic liner. This type of impingement, unlike impingements with a stem neck, has not been previously reported. While we assume that certain characteristics of the stem contributed to the impingement, we report this case to note that caution may be needed when using certain stem designs.<br />Competing Interests: CONFLICT OF INTEREST: The authors declare that there is no potential conflict of interest relevant to this article.<br /> (Copyright © 2020 by Korean Hip Society.)

Details

Language :
English
ISSN :
2287-3260
Volume :
32
Issue :
3
Database :
MEDLINE
Journal :
Hip & pelvis
Publication Type :
Report
Accession number :
32953708
Full Text :
https://doi.org/10.5371/hp.2020.32.3.156