Back to Search
Start Over
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
- Source :
-
PloS one [PLoS One] 2020 Sep 08; Vol. 15 (9), pp. e0238951. Date of Electronic Publication: 2020 Sep 08 (Print Publication: 2020). - Publication Year :
- 2020
-
Abstract
- The aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smokers male subjects with overnight fasting of >10hr. The study was a randomized, single-dose, open-label, two sequence, and two treatment crossover design, with a washout period of 2 weeks. Blood samples (5 mL) from the human subjects were collected before (0 hr) and after drug administration at 13different time points (0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 12 and 18 hrs). The drug plasma concentration was analyzed by a validated RP-HPLC method using a solvent system containing acetonitrile and deionized water (60:40% v/v). Linearity was found to be 0.999 over the drug concentration range of 50μg/mL to 0.05μg/mL with LLOQ and LOD of 0.05μg/mL and 0.025μg/mL respectively. Non-compartmental pharmacokinetic analysis was performed using Kinetica® (ver. 5.1) software. Using the log-transformed data Cmax, AUC0-t, AUC0-∞, AUMCtot, and MRT were calculated. The Cmax of the test and brand was found to be 8.629±1.251μg/mL and 8.478±0.913μg/mL. The AUC0-t and AUC0-∞ of the test and the reference were computed to be 20.890 ±2.2021μg/mL.h, 23.272 ±1.914 μg/mL.h and 19.850 ±2.911 μg/mL.h, 22.890 ± 2.110 μg/mL.h correspondingly. Two-way analysis of variance (ANOVA) test and two one-sided t-test (p>0.05; non-significant) were applied to assess the variation in the period, sequence, subjects, and treatment. Geometric mean ratios for above mentioned pharmacokinetic parameters of reference/test were found within the acceptable FDA limits of 80-125% using 90% CI. There was no inter and intrasubject variation (p> 0.05) that was observed. Therefore, the directly compressible aceclofenac (100 mg) test formulation and the commercial reference tablets were declared to be biosimilar.<br />Competing Interests: The authors have declared that no competing interests exist.
- Subjects :
- Adult
Analysis of Variance
Area Under Curve
Chemistry, Pharmaceutical methods
Chromatography, High Pressure Liquid methods
Cross-Over Studies
Diclofenac metabolism
Diclofenac pharmacokinetics
Healthy Volunteers
Humans
Male
Tablets pharmacokinetics
Therapeutic Equivalency
Diclofenac analogs & derivatives
Subjects
Details
- Language :
- English
- ISSN :
- 1932-6203
- Volume :
- 15
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- PloS one
- Publication Type :
- Academic Journal
- Accession number :
- 32898192
- Full Text :
- https://doi.org/10.1371/journal.pone.0238951