Back to Search Start Over

Distribution of C-arm projections in native and bioprosthetic aortic valves cusps: Implication for BASILICA procedures.

Authors :
Komatsu I
Tang GHL
Leipsic J
Webb JG
Blanke P
Mackensen GB
Kitamura M
Wolak A
Don CW
McCabe JM
Rumer C
Tan CW
Levin DB
Ramos M
Aldea GS
Reisman M
Wijeysundera HC
Radhakrishnan S
Sathananthan J
Piazza N
Kornowski R
Abdel-Wahab M
Dvir D
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2021 Mar; Vol. 97 (4), pp. E580-E587. Date of Electronic Publication: 2020 Sep 07.
Publication Year :
2021

Abstract

Objectives: We sought to document aortic cusps fluoroscopic projections and their distributions using leaflet alignment which is a novel concept to optimize visualization of leaflets and for guiding BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction) and determine whether these projections were feasible in catheter laboratory.<br />Background: Optimal fluoroscopic projections of aortic valve cusps have not been well described.<br />Methods: A total of 128 pre-transcatheter aortic valve replacement (pre-TAVR) computed tomographies (CT) (72 native valves and 56 bioprosthetic surgical valves) were analyzed. Using CT software (3Mensio, Pie medical imaging, the Netherlands), leaflet alignment was performed and the feasibility of these angles, which were defined as rate of obtainable with efforts (within LAO/RAO of 85° and CRA/CAU of 50°) were evaluated.<br />Results: High feasibility was seen in right coronary cusp (RCC) front view (100%) and left coronary cusp (LCC) side view (99.2%), followed by noncoronary cusp side view (95.3%). In contrast, low feasibility of RCC side view (7.8%) and LCC front view (47.6%) was observed. No statistical differences were seen between the distribution of native valves and bioprosthetic surgical valves. With patient/table tilt of 20°LAO and 10°CRA, the feasibility of RCC side view and LCC front view increased to 43.7 and 85.2%, respectively.<br />Conclusion: Distributions of each cusp's leaflet alignment follows "sigmoid curve" which can provide better understanding of aortic valve cusp orientation in TAVR and BASILICA. RCC side view used in right cusp BASILICA is commonly unachievable in catheter laboratory and may improve with patient/table tilt.<br /> (© 2020 Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1522-726X
Volume :
97
Issue :
4
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
32894804
Full Text :
https://doi.org/10.1002/ccd.29224