Back to Search Start Over

A urine-based Exosomal gene expression test stratifies risk of high-grade prostate Cancer in men with prior negative prostate biopsy undergoing repeat biopsy.

Authors :
McKiernan J
Noerholm M
Tadigotla V
Kumar S
Torkler P
Sant G
Alter J
Donovan MJ
Skog J
Source :
BMC urology [BMC Urol] 2020 Sep 01; Vol. 20 (1), pp. 138. Date of Electronic Publication: 2020 Sep 01.
Publication Year :
2020

Abstract

Background: Initial prostate biopsy often fails to identify prostate cancer resulting in patient anxiety, especially when clinical features such as prostate specific antigen (PSA) remain elevated, leading to the need for repeat biopsies. Prostate biomarker tests, such as the ExoDx™ Prostate (IntelliScore), or EPI test, have been shown to provide individualized risk assessment of clinically significant prostate cancer at initial biopsy; however, the performance in the repeat biopsy setting is not well established.<br />Methods: As part of a previous prospective clinical validation study evaluating the performance of the EPI test, we collected first-catch, non-DRE urine samples across 22 sites from men with at least one prior negative biopsy scheduled to undergo a repeat prostate biopsy to rule out prostate cancer. All men were 50 years or older with a PSA 2-10 ng/mL. Exosomal mRNA was extracted and expression of three genomic markers, PCA3, ERG and SPDEF was measured. The resulting EPI score was correlated with biopsy results.<br />Results: 229 men with a prior negative biopsy underwent repeat biopsies. ExoDx Prostate demonstrated good performance ruling out high-grade (Grade group 2, GG2, or higher) prostate cancer (HGPCa) using the previously validated 15.6 cut point in the initial biopsy setting. The EPI test yielded an NPV of 92% independent of other clinical features and would have avoided 26% of unnecessary biopsies while missing only five patients with HGPCa (2.1%). Furthermore, the EPI test provided additional information at a cut-point of 20 and 29.6 with an NPV of 94%, potentially delaying 35 and 61% of unnecessary biopsies, respectively. AUC curves and Net Health Benefit Analyses demonstrated superior performance of ExoDx Prostate over PSA and clinical only risk calculators, i.e. ERSPC.<br />Conclusions: The EPI test provided good performance using the 15.6 cut-point for ruling out HGPCa / GG2 or higher in men undergoing a repeat prostate biopsy with a PSA of 2-10 ng/ml. Furthermore, the test utilizes gene expression data independent of clinical features to predict the likelihood of HGPCa / GG2 on a subsequent needle biopsy.

Details

Language :
English
ISSN :
1471-2490
Volume :
20
Issue :
1
Database :
MEDLINE
Journal :
BMC urology
Publication Type :
Academic Journal
Accession number :
32873277
Full Text :
https://doi.org/10.1186/s12894-020-00712-4