Back to Search Start Over

Keratoconus Detection Based on a Single Scheimpflug Image.

Authors :
Consejo A
Solarski J
Karnowski K
Rozema JJ
Wojtkowski M
Iskander DR
Source :
Translational vision science & technology [Transl Vis Sci Technol] 2020 Jun 26; Vol. 9 (7), pp. 36. Date of Electronic Publication: 2020 Jun 26 (Print Publication: 2020).
Publication Year :
2020

Abstract

Purpose: To introduce a new approach for keratoconus detection based on corneal microstructure observed in vivo derived from a single Scheimpflug image.<br />Methods: Scheimpflug single-image snapshots from 25 control subjects and 25 keratoconus eyes were analyzed; from each group, five subjects were randomly selected to provide out-of-sample data. Each corneal image was segmented, after which the stromal pixel intensities were statistically modeled with a Weibull distribution. Distribution estimated parameters α and β , characterizing corneal microstructure, were used in combination with a macrostructure parameter, central corneal thickness (CCT), for the detection of keratoconus. In addition, receiver operating characteristic curves were used to determine the sensitivity and specificity of each parameter for keratoconus detection.<br />Results: The combination of CCT (sensitivity = 88%; specificity = 84%) with microscopic parameters extracted from statistical modeling of light intensity distribution, α (sensitivity = 76%; specificity = 76%) and β (sensitivity = 96%; specificity = 88%), from a single Scheimpflug image was found to be a successful tool to differentiate between keratoconus and control eyes with no misclassifications (sensitivity = 100%; specificity = 100%) with coefficients of variation up to 2.5%.<br />Conclusions: The combination of microscopic and macroscopic corneal parameters extracted from a static Scheimpflug image is a promising, non-invasive tool to differentiate corneal diseases without the need to perform measurements based on induced deformation of the corneal structure.<br />Translational Relevance: The proposed methodology has the potential to support clinicians in the detection of keratoconus, without compromising patient comfort.<br />Competing Interests: Disclosure: A. Consejo, None; J. Solarski, None; K. Karnowski, None; J.J. Rozema, None; M. Wojtkowski, None; D.R. Iskander, None<br /> (Copyright 2020 The Authors.)

Details

Language :
English
ISSN :
2164-2591
Volume :
9
Issue :
7
Database :
MEDLINE
Journal :
Translational vision science & technology
Publication Type :
Academic Journal
Accession number :
32832241
Full Text :
https://doi.org/10.1167/tvst.9.7.36