Back to Search Start Over

A 96-Monolithic inorganic hollow fiber array as a new geometry for high throughput solid-phase microextraction of doxorubicin in water and human urine samples coupled with liquid chromatography-tandem mass spectrometry.

Authors :
Rahmani F
Hosseini MM
Es-Haghi A
Mollahosseini A
Source :
Journal of chromatography. A [J Chromatogr A] 2020 Sep 13; Vol. 1627, pp. 461413. Date of Electronic Publication: 2020 Jul 15.
Publication Year :
2020

Abstract

Innovations in extraction phases, extraction modes and hyphenated instrument configurations, are the most important issues to address for progress in the solid phase microextraction (SPME) methodology. In this regard, we have embarked on the development of a novel biocompatible 96-monolithic inorganic hollow fiber (96-MIHF) array as a new configuration for high-throughput SPME on a 96-well plate system. An arrangement of highly ordered 96 titania/Hydroxyapatite (TiO <subscript>2</subscript> /HAP) nanocomposite hollow fibers and corresponding stainless-steel needles on a Teflon plate holder were used as the extraction module. The inorganic hollow fibers were prepared via a rapid and reproducible template approach (Polypropylene hollow fiber) in combination with a sol-gel method in the presence of polyvinyl alcohol (PVA), as a network maker. The hollow fiber-shape sorbents were obtained with excellent precision by weight (RSD% = 4.98, n = 10) and length (RSD% = 1.08, n = 10) criteria. The proposed design can overcome a number of geometrically dependent drawbacks of conventional high-throughput SPME methods, mainly the ones related to sorbent amount and surface area due to possessing inner/outer surfaces without additional internal supports. The SPME platform, for the first time, was successfully applied for the extraction and preconcentration of doxorubicin from urine and water media without requiring sample preparation and free from significant matrix effect. The extracted analyte was analyzed by liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS). Highly satisfactory analytical figures of merit were obtained under optimized conditions. The limit of detection (LOD), limit of quantification (LOQ) and linearity of determination were 0.1 ng mL <superscript>-1</superscript> , 0.25 ng mL <superscript>-1</superscript> and 0.25 to 4000 ng mL <superscript>-1</superscript> , respectively. The interday, intraday and inter sorbent precisions for three concentration levels ranged from 2.01 to 8.09 % (n = 3), 1.02 to 8.65 % (n = 5) and 0.99 to 1.02% (n = 15), respectively. The mean intra-well RSD value for 96 individual wells in 96-MIHF-SPME-LC-MS/MS (n = 3) at the medium concentration level was 7.81%.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2020. Published by Elsevier B.V.)

Details

Language :
English
ISSN :
1873-3778
Volume :
1627
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
32823111
Full Text :
https://doi.org/10.1016/j.chroma.2020.461413