Back to Search Start Over

Home Monitoring of Age-Related Macular Degeneration: Utility of the ForeseeHome Device for Detection of Neovascularization.

Authors :
Yu HJ
Kiernan DF
Eichenbaum D
Sheth VS
Wykoff CC
Source :
Ophthalmology. Retina [Ophthalmol Retina] 2021 Apr; Vol. 5 (4), pp. 348-356. Date of Electronic Publication: 2020 Aug 15.
Publication Year :
2021

Abstract

Purpose: To evaluate the real-world utility of the ForeseeHome monitoring device (Notal Vision, Ltd., Tel Aviv, Israel) for the detection of conversion from intermediate age-related macular degeneration (iAMD) to neovascular AMD (nAMD) and to compare with results published by the Home Monitoring of the Eye (HOME) study.<br />Design: Retrospective analysis of electronic health records.<br />Participants: Eyes prescribed use of the ForeseeHome device across 4 retinal practices in the United States.<br />Methods: Usage information was collected from the online ForeseeHome portal for all eyes prescribed the device. For a predetermined subset of eyes, additional clinical information was collected through chart review and analyzed for clinical utility.<br />Main Outcome Measures: Frequency and length of use, number of eyes that used the device, number of eyes that established a baseline measurement, number of eyes that converted to nAMD, and number of alerts.<br />Results: Seven hundred seventy-five eyes of 448 patients were prescribed use of the ForeseeHome device. Six hundred forty-nine eyes (83.7%) used the device at least once; among this population, 478 (73.7%) established a baseline measurement. Patients who established a baseline measurement were significantly younger than those who did not (P < 0.001). Among eyes that established a baseline measurement, 126 (26.4%) had an overall inadequate frequency of use (≥2 tests per week), and 250 (52.3%) did not use the device as frequently as instructed by the manufacturer (≥3 tests per week); 24.7% of eyes discontinued use within 1 year. Of the 136 eyes that established a baseline measurement among 211 eyes prescribed the device at 1 clinical site, 52 alerts were recorded; 3 (6.8%) correctly identified conversion to nAMD and 47 (93.2%) represented false-positive alerts.<br />Conclusions: Compared with the prospective HOME study, the utility of the ForeseeHome device in the current analysis of clinical practice application was limited. A meaningful proportion of eyes never used the device or could not establish a baseline measurement. Overall frequency of use was low, and continuous use of the device decreased over time. A need exists for improvement in home monitoring technology for eyes with iAMD at risk of conversion to nAMD.<br /> (Copyright © 2020 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
2468-6530
Volume :
5
Issue :
4
Database :
MEDLINE
Journal :
Ophthalmology. Retina
Publication Type :
Academic Journal
Accession number :
32810682
Full Text :
https://doi.org/10.1016/j.oret.2020.08.003