Back to Search
Start Over
Macintosh Videolaryngoscope for Intubation in the Operating Room: A Comparative Quality Improvement Project.
- Source :
-
Anesthesia and analgesia [Anesth Analg] 2021 Feb 01; Vol. 132 (2), pp. 524-535. - Publication Year :
- 2021
-
Abstract
- Background: "Macintosh"-videolaryngoscopes (VLs) are VLs that allow both direct and indirect laryngoscopy for intubation. We describe the decision-making and implementation-processes that our hospital used regarding the choice of device. We compared the performances of 4 Macintosh-VLs both in direct and indirect laryngoscopy.<br />Methods: A quality-improvement-project for airway management aiming at implementing Macintosh-VL for all intubation procedures performed in the operating room, involving 4 Macintosh-VLs (McGrath-Mac, C-MAC-S, C-MAC-S-Pocket-Monitor [PM], and APA). Three consecutive steps were described: (1) direct laryngoscopy with Macintosh-VL, (2) indirect laryngoscopy with Macintosh-VL (intubation attempt with Macintosh-style blade in case of Cormack I or II), (3) intubation attempt with hyperangulated blade in case of Cormack III/IV or failure of Macintosh-style blade. The main end point was the need to move to step III and use a hyperangulated blade. A mixed-effects multivariable logistic regression analysis was performed to compare devices on the main end point while considering site as a random effect. Comparison of means was performed using analysis of variance and Tukey's test for multiple comparisons (number of laryngoscopy attempts, numeric rate scale [NRS] difficulty of intubation and NRS user-friendliness). Comparison of percentages was performed using a χ2 test for the need to move to step III and a Kruskal-Wallis test for the quality of image (bad, passable, good, very good, excellent). A P value ≤.008 was considered statistically significant.<br />Results: From May to September 2017, 589 patients were included. Using the McGrath-Mac (22/180 [12%]) was associated with less use of hyperangulated blade than using the C-MAC-S (39/132 [30%], odds ratio [OR] [99.2% confidence interval {CI}] 0.34 [0.16-0.77], P = .0005), the APA (35/138 [25%], OR [99.2% CI] 0.42 [0.19-0.93]; P = .004), but not the C-MAC-S-PM (29/139 [21%], OR [99.2% CI] 0.53 [0.23-1.2]; P = .04).Overall, the number of intubation attempts was significantly lower using the McGrath Mac than the C-MAC-S or the C-MAC-S-PMVLs. Subjective appreciation of intubation difficulty and user-friendliness of the devices showed respectively lower and higher NRS scores for the McGrath-Mac compared to the other devices, whereas subjective assessment of image quality showed higher quality for the C-MAC-S and C-MAC-S-PM compared to the APA or McGrath-Mac.<br />Conclusions: Among 4 single-use Macintosh-VLs, glottic visualization in direct and indirect laryngoscopy with the Macintosh-style blade was significantly improved with the McGrath-Mac compared to other Macintosh-VLs, leading to a less frequent need to resort to the hyperangulated blade and reduced overall number of intubation attempts.<br />Competing Interests: Conflicts of Interest: See Disclosures at the end of the article.<br /> (Copyright © 2020 International Anesthesia Research Society.)
- Subjects :
- Adult
Aged
Female
Humans
Intubation, Intratracheal adverse effects
Intubation, Intratracheal standards
Laryngoscopy adverse effects
Laryngoscopy standards
Male
Middle Aged
Video Recording standards
Intubation, Intratracheal instrumentation
Laryngoscopes standards
Laryngoscopy instrumentation
Operating Rooms standards
Quality Improvement standards
Quality Indicators, Health Care standards
Video Recording instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1526-7598
- Volume :
- 132
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Anesthesia and analgesia
- Publication Type :
- Academic Journal
- Accession number :
- 32739955
- Full Text :
- https://doi.org/10.1213/ANE.0000000000005031