Back to Search Start Over

Use of IMAGE1 S technology for detection of cholesteatoma in endoscopic ear surgery: a retrospective case series on 45 patients.

Authors :
Lucidi D
Fernandez IJ
Martone A
Molinari G
Bonali M
Villari D
Alicandri-Ciufelli M
Presutti L
Source :
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery [Eur Arch Otorhinolaryngol] 2021 May; Vol. 278 (5), pp. 1373-1380. Date of Electronic Publication: 2020 Jul 14.
Publication Year :
2021

Abstract

Purpose: To evaluate the role of selected modalities of Storz Professional Image Enhancement System (IMAGE1 S) in differentiating cholesteatoma during endoscopic ear surgery (EES); to assess the potential usefulness of IMAGE1 S in recognition of cholesteatoma residuals at the end of EES.<br />Methods: A retrospective study on 45 consecutive patients who underwent EES for cholesteatoma between March 2019 and November 2019 at a tertiary referral center was performed. For each case, Spectra A and Spectra B filters were applied intra-operatively. When examining the surgical field, a switch from white light (WL) to IMAGE1 S was performed to detect cholesteatoma and differentiate it from non-cholesteatomatous tissue. When the IMAGE1 S pattern was suspicious for the presence of cholesteatoma, images of the field under both enhancement modalities were taken and the targeted lesions were sent for histologic analysis. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of IMAGE1 S were calculated. A final recognition of the surgical field using the selected filters was performed to detect any possible cholesteatomatous residuals.<br />Results: Detection of cholesteatoma by IMAGE1 S selected filters revealed the following data: sensitivity 97%, specificity 95%, PPV 95%, NPV 97%. On three occasions, there was no correspondence between enhanced endoscopy and histology. In 5 out of 45 cases (11%), cholesteatoma residuals, which had not been identified at WL inspection at the end of the procedure, were detected by IMAGE1 S.<br />Conclusion: Our results suggest a potential role for IMAGE1 S Spectra A and B filters in EES for cholesteatoma surgery. We propose the integration of IMAGE1 S as a final overview of the surgical cavity for recognition of cholesteatomatous residuals.

Details

Language :
English
ISSN :
1434-4726
Volume :
278
Issue :
5
Database :
MEDLINE
Journal :
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
Publication Type :
Academic Journal
Accession number :
32666292
Full Text :
https://doi.org/10.1007/s00405-020-06204-3