Back to Search Start Over

Echocardiographic and hemodynamic indices of myocardial contractility simultaneously evaluated in telemetered beagle dogs: A HESI-sponsored cross-company evaluation.

Authors :
Rossman EI
Cools F
Cordes J
Dhuyvetter D
Doyle JM
Friedrichs GS
Guth B
Neradilek MB
Parish ST
Pierson JB
Polissar N
Tang HM
Source :
Journal of pharmacological and toxicological methods [J Pharmacol Toxicol Methods] 2020 Sep; Vol. 105, pp. 106897. Date of Electronic Publication: 2020 Jul 12.
Publication Year :
2020

Abstract

Introduction: Alterations in cardiac contractility can have significant clinical implications, highlighting the need for early detection of potential liabilities. Pre-clinical methods to assess contractility are typically invasive and their translation to human measures of cardiac function are not well defined. Clinically, cardiac function is most often measured non-invasively using echocardiography. The objective of these studies was to introduce echocardiography into standard large animal cardiovascular safety pharmacology studies and determine the feasibility of this combination.<br />Methods: A consortia of laboratories combined their data sets for evaluation. At each site, telemetered beagle dogs, in a 4 × 4 Latin square crossover study design (n = 4), were administered either pimobendan (positive inotrope) or atenolol (negative inotrope) orally at clinically relevant dose levels. Standard telemetry parameters were collected (heart rate, mean arterial blood pressure, etc.) continuously over 24 h, as well as derived contractility endpoints: QA interval and LV +dP/dt <subscript>max</subscript> . At T <subscript>max</subscript> , echocardiography was performed in conscious dogs with minimal restraint to collect contractility parameters: ejection fraction (EF) and fractional shortening (FS).<br />Results: Correlations between telemetry and echo contractility endpoints showed that, in general, a change in LV +dP/dt <subscript>max</subscript> of 1000 mmHg/s translates to a 5.2% change in EF and a 4.2% change in FS. Poor correlations were shown between QA interval derived simultaneously, to both EF and FS.<br />Discussion: Comparing data from telemetry-only groups to those that included echocardiography collections showed no effect in the ability to interpret test article-related effects, providing the foundation for the inclusion of echocardiography without compromising standard telemetry data quality.<br />Competing Interests: Declaration of Competing Interest Unless otherwise specified, the authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2020 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1873-488X
Volume :
105
Database :
MEDLINE
Journal :
Journal of pharmacological and toxicological methods
Publication Type :
Academic Journal
Accession number :
32663523
Full Text :
https://doi.org/10.1016/j.vascn.2020.106897