Abstract
- Introduction: Removal of uremic toxins is a main objective of hemodialysis; however, whether high-flux and medium cut-off (MCO) membranes differ as regards removal of middle and large uremic toxins is not clear.<br />Objective: To compare medium cut-off and high-flux dialyzers as regards their intra- and interdialysis effect on circulating levels of middle and large uremic toxins and serum albumin.<br />Methods: Fifty-two patients were randomized to have hemodialysis with either 3 months of high-flux dialyzer followed by 3 months of MCO or vice versa. Blood samples were taken before and after dialysis at the first and last sessions of each dialyzer for analyses of middle and large uremic toxins including inflammatory mediators and vascular endothelial growth factor (VEGF), and serum albumin.<br />Results: Reduction rates were higher, and postdialysis levels of β-2 microglobulin, free kappa and lambda light chains, and myoglobulin were lower at the first and last sessions with MCO dialyzers compared to high-flux dialyzers (p < 0.05 for all). Last session predialysis levels of β-2 microglobulin, free kappa light chain, and free lambda light chain were lower than first session predialysis levels in MCO dialyzers as compared to high-flux dialyzers (p < 0.05 for all). Last session levels of interleukin-6, interleukin-10, interleukin-17, and interferon-gamma did not differ between dialyzers (p > 0.05 for all). VEGF level was lower in the MCO group compared to the high-flux group (p = 0.043). Last session level of serum albumin with MCO dialyzers was lower than that with high-flux dialyzers (3.62 [3.45-3.88] vs. 3.78 [3.58-4.02] g/L) (p = 0.04) and 6.7% lower (p < 0.001) than at the first session of MCO dialyzers.<br />Conclusion: The decline in circulating levels of several middle and large uremic toxins including VEGF following hemodialysis was more pronounced when using MCO membranes as compared to high-flux membranes while their effect on inflammatory molecules was similar.<br /> (© 2020 S. Karger AG, Basel.)
- Subjects :
- Adult
Aged
Biomarkers
Comorbidity
Cytokines metabolism
Female
Humans
Male
Middle Aged
Randomized Controlled Trials as Topic
Serum Albumin
Uremia etiology
Uremia therapy
Vascular Endothelial Growth Factor A blood
beta 2-Microglobulin blood
Hemodiafiltration methods
Membranes, Artificial
Renal Dialysis methods
Toxins, Biological blood
Uremia blood
Subjects
Details
- Language :
- English
- ISSN :
- 1421-9735
- Volume :
- 49
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Blood purification
- Publication Type :
- Academic Journal
- Accession number :
- 32634815
- Full Text :
- https://doi.org/10.1159/000508061