Back to Search
Start Over
Characterizing a PTW microDiamond detector in kilovoltage radiation beams.
- Source :
-
Medical physics [Med Phys] 2020 Sep; Vol. 47 (9), pp. 4553-4562. Date of Electronic Publication: 2020 Jul 13. - Publication Year :
- 2020
-
Abstract
- Purpose: The aim of this work was to characterize the dosimetric properties of the PTW microDiamond (60019) single crystal synthetic diamond detector (DD) in kilovoltage x-ray beams. The following characteristics were addressed in this study: required preirradiation dose, dose-rate linearity, energy dependence, and percent depth dose response of the DD.<br />Methods: UWADCL x-ray beams, characterized by NIST-traceable ionization chambers, were used in this study. Preirradiation dose required by the DD, in order to stabilize the detector's response to within 0.1%, was quantitated. Dose-rate dependence was also investigated using the UW250-M and UW50-M beams, where the dose rate was varied by changing the tube current. N k and N D , w calibration coefficients for all the available M series beams at UWADCL were obtained to determine the energy dependence of the DD, Diode E, Diode P, and P11 parallel-plate ionization chamber. A custom-built water tank was utilized to measure the percent depth dose (PDD) response of the DD, Diode E, Diode P, and P11 chamber in UW250-M, UW100-M, and UW50-M beams. The measured PDD response of the detectors was compared with the simulated PDD data using EGSnrc Monte Carlo code.<br />Results: A 1.5 Gy dose-to-water or air-kerma was found to be sufficient for the given DD's response to stabilize to within 0.1% in all of the beams used in this study. The dose-rate dependence parameter, Δ, was found to be 1.00 ± 0.02 and 1.016 ± 0.05 for the UW250-M and UW50-M beams, respectively. Relative to the 60 Co calibration coefficients, the DD was found to under-respond relative to calculated absorbed dose to water response and over-respond relative to the calculated air-kerma response in the M-series beams. Agreement of 1.5% was found between the measured PDD values and Monte Carlo simulated PDD values for UW250-M, UW100-M, and UW50-M beams.<br />Conclusions: In order to stabilize the response, the DD needs a preirradiation dose, which is unique to every DD. A linear relationship between detector response and dose rate was found within the evaluated uncertainty. An energy dependence of the DD was studied, which is more pronounced in the low-energy beams and can be partially attributed to the metal contact material around the sensitive volume of the DD. Overall, the DD was found to be suitable for kilovoltage x-ray dosimetry.<br /> (© 2020 American Association of Physicists in Medicine.)
- Subjects :
- Calibration
Monte Carlo Method
Photons
X-Rays
Diamond
Radiometry
Subjects
Details
- Language :
- English
- ISSN :
- 2473-4209
- Volume :
- 47
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Medical physics
- Publication Type :
- Academic Journal
- Accession number :
- 32557666
- Full Text :
- https://doi.org/10.1002/mp.14330