Back to Search
Start Over
Do surface electrodes validly represent lower trapezius activation patterns during shoulder tasks?
- Source :
-
Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology [J Electromyogr Kinesiol] 2020 Aug; Vol. 53, pp. 102427. Date of Electronic Publication: 2020 May 19. - Publication Year :
- 2020
-
Abstract
- Because of its superficial location, surface electrodes are commonly used to record lower trapezius activity. Recent evidence, however, would suggest that surface electromyography is not a valid to record activity from other superficially placed shoulder muscles. Therefore, the aim of this study was to determine the validity of using surface electrodes to record lower trapezius activity. Ten asymptomatic subjects performed ramped isometric (0-100% maximum load) and dynamic (70% maximum load) shoulder tasks. Intramuscular electrodes were inserted into lower trapezius and rhomboid major. Surface electrodes were placed over lower trapezius around the intramuscular electrodes. Differences in the recorded activity of lower trapezius between surface and intramuscular electrodes were tested using a 2 factor repeated measures analysis of variance with factors: test and electrode type. Similarity in the recorded activity patterns between the two electrodes was tested using Pearson's correlation coefficient (r). Results indicated that there was no difference in lower trapezius activity levels (p = 0.98) or activation patterns (r ≥ 0.74) recorded by the intramuscular and surface electrodes. The results of this study indicate that any potential crosstalk contamination in the surface electrode signal is having little influence on the recorded activity from lower trapezius and therefore, support the common practice of surface electromyography to investigate lower trapezius function.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2020 Elsevier Ltd. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-5711
- Volume :
- 53
- Database :
- MEDLINE
- Journal :
- Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
- Publication Type :
- Academic Journal
- Accession number :
- 32470865
- Full Text :
- https://doi.org/10.1016/j.jelekin.2020.102427