Back to Search Start Over

Inappropriate Nasopharyngeal Sampling for SARS-CoV-2 Detection Is a Relevant Cause of False-Negative Reports.

Authors :
Piras A
Rizzo D
Uzzau S
De Riu G
Rubino S
Bussu F
Source :
Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery [Otolaryngol Head Neck Surg] 2020 Sep; Vol. 163 (3), pp. 459-461. Date of Electronic Publication: 2020 May 26.
Publication Year :
2020

Abstract

Reverse transcriptase polymerase chain reaction (RT-PCR) detection of SARS-CoV-2 mRNA on nasopharyngeal swab is the standard for diagnosing active COVID-19 disease in asymptomatic cases and in symptomatic patients without the typical radiologic findings. For the present COVID-19 outbreak in Italy, we describe 4 symptomatic patients with negative RT-PCR results at the first nasopharyngeal swab, which became positive when collected a few hours later by an otolaryngologist. All the patients showed nasal obstruction. The present report suggests that inadequate nasopharyngeal sampling performed by untrained operators in the presence of nasal obstruction can be a relevant case of false-negative findings at RT-PCR, with a clear negative impact on the efforts to contain the current outbreak.

Details

Language :
English
ISSN :
1097-6817
Volume :
163
Issue :
3
Database :
MEDLINE
Journal :
Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
Publication Type :
Academic Journal
Accession number :
32450754
Full Text :
https://doi.org/10.1177/0194599820931793