Back to Search
Start Over
Shoulder outcome scoring systems have substantial ceiling effects 2 years after arthroscopic rotator cuff repair.
- Source :
-
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA [Knee Surg Sports Traumatol Arthrosc] 2021 Jul; Vol. 29 (7), pp. 2070-2076. Date of Electronic Publication: 2020 May 21. - Publication Year :
- 2021
-
Abstract
- Purpose: Previous studies show no difference in clinical outcomes between patients with healed and structurally failed rotator cuff repairs. The objective of this study was to assess ceiling effects when reporting surgical outcomes of arthroscopic rotator cuff repair using four of the currently most popular clinical shoulder outcome scoring systems.<br />Methods: Ninety-two patients who underwent arthroscopic rotator cuff repair were examined. The simple shoulder test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder rating scale, and Constant-Murley shoulder score were completed 2 years postoperatively. Demographic data of the subjects were analysed using descriptive statistics. The ceiling effects in the outcome data assessed for each scale were estimated based on two previously reported definitions.<br />Results: The number of patients with the maximum possible score was 31 (33.7%) with the SST, 26 (28.3%) with the ASES score, 28 (30.4%) with the UCLA scale, and 18 (19.6%) with the Constant-Murley score. The standardised distance of the outcome data assessed by the SST, ASES score, UCLA scale, and Constant-Murley scores were 0.92, 0.97, 0.96, and 1.18, respectively.<br />Conclusion: The SST, ASES score, and UCLA scale evaluated at 2 years postoperatively have substantial ceiling effects showing that the proportion of patients with the maximum possible score is > 20%, and the standardised distance is < 1.0. Researchers should be aware of possible biases due to ceiling effects when interpreting the results of studies investigating the surgical outcomes of arthroscopic rotator cuff repair. It could increase the likelihood of a type II error.<br />Level of Evidence: IV.
- Subjects :
- Aged
Female
Humans
Male
Middle Aged
Muscle Strength
Postoperative Period
Prospective Studies
Range of Motion, Articular
Rotator Cuff surgery
Shoulder surgery
Shoulder Joint physiopathology
Shoulder Joint surgery
Shoulder Pain physiopathology
Treatment Outcome
Arthroscopy methods
Rotator Cuff Injuries surgery
Shoulder physiopathology
Subjects
Details
- Language :
- English
- ISSN :
- 1433-7347
- Volume :
- 29
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA
- Publication Type :
- Academic Journal
- Accession number :
- 32440715
- Full Text :
- https://doi.org/10.1007/s00167-020-06036-y