Back to Search Start Over

Sonographic assessment of calcium pyrophosphate deposition disease at wrist. A focus on the dorsal scapho-lunate ligament.

Authors :
Cipolletta E
Smerilli G
Mashadi Mirza R
Di Matteo A
Carotti M
Salaffi F
Grassi W
Filippucci E
Source :
Joint bone spine [Joint Bone Spine] 2020 Dec; Vol. 87 (6), pp. 611-617. Date of Electronic Publication: 2020 May 11.
Publication Year :
2020

Abstract

Objectives: To investigate the diagnostic accuracy of ultrasound and conventional radiography in the evaluation of calcium pyrophosphate crystal deposits at wrist level.<br />Methods: Consecutive patients with a "definite" diagnosis of calcium pyrophosphate deposition disease and disease-controls were prospectively included in this cross-sectional single-centre study. Scapho-lunate ligament, triangular fibrocartilage complex, and volar recess of the radio-lunate joint were explored using ultrasound, conventional radiography and computed tomography.<br />Results: Sixty one patients and 39 disease controls were enrolled. Two-hundred wrists were evaluated using both conventional radiography and ultrasound and 26 using computed tomography. Ultrasound findings indicative of crystal deposits were found in at least one wrist in 95.1% of patients and in 15.4% of controls (P<0.001). Scapho-lunate ligament calcifications were reported in 83.6% of patients and in 5.1% of controls (P<0.001). On conventional radiography, calcifications were found in at least one wrist in 72.1% of patients and in 0% of controls (P<0.001). Using the Ryan-McCarty criteria as a gold standard, sensitivity, specificity and diagnostic accuracy were 0.72 (0.59-0.83), 1.0 (0.91-1.0) and 0.83 (0.74-0.90) for conventional radiography and 0.95 (0.86-0.99), 0.85 (0.69-0.94) and 0.91 (0.84-0.96) for ultrasound. The agreement between ultrasound and computed tomography was substantial when assessing triangular fibrocartilage complex (kappa=0.70; 0.43-0.97) and scapho-lunate ligament (kappa=0.69; 0.41-0.97), and moderate for radio-lunate joint (kappa=0.46; 0.12-0.80).<br />Conclusions: This study supports the diagnostic accuracy of ultrasound in evaluating wrist involvement in calcium pyrophosphate deposition disease. The inclusion of the scapho-lunate ligament in a disease-oriented scanning protocol could improve the diagnostic performance of ultrasound.<br /> (Copyright © 2020 Société française de rhumatologie. Published by Elsevier Masson SAS. All rights reserved.)

Details

Language :
English
ISSN :
1778-7254
Volume :
87
Issue :
6
Database :
MEDLINE
Journal :
Joint bone spine
Publication Type :
Academic Journal
Accession number :
32438060
Full Text :
https://doi.org/10.1016/j.jbspin.2020.04.012