Back to Search Start Over

Prostatic Artery Embolization for Benign Prostatic Hyperplasia: Bleomycin-Eluting versus Bland Microspheres in a Canine Model.

Authors :
Zhang JL
Yuan B
Wang MQ
Fu JX
Duan F
Wang T
Shen L
Wang Y
Liu JH
Shen YG
Wang XQ
Zhang HT
Li HW
Yan JY
Song ZG
Source :
Journal of vascular and interventional radiology : JVIR [J Vasc Interv Radiol] 2020 May; Vol. 31 (5), pp. 820-830. Date of Electronic Publication: 2020 Apr 15.
Publication Year :
2020

Abstract

Purpose: To prospectively assess safety and efficacy of prostatic artery embolization (PAE) with bleomycin-eluting microspheres for benign prostatic hyperplasia (BPH) in a canine model.<br />Materials and Methods: Twelve adult male beagles (mean age, 1.6 y ± 0.2; range, 1.2-2.0 y) were randomly assigned to group A (n = 6; PAE with bleomycin-eluting 30-60-μm HepaSphere microspheres) and group B (n = 6; PAE with bland 30-60-μm HepaSphere microspheres) between April 2017 and November 2018. Plasma bleomycin concentration in group A was measured within 7 days. Prostate volume (PV) and ischemic volume after PAE were measured by magnetic resonance imaging. Prostates and adjacent organs were harvested after the last magnetic resonance study and histopathologically examined.<br />Results: Plasma bleomycin concentration peaked at 10 minutes at 2,055.0 ng/mL ± 606.1 and lasted for 1,440 min at low levels after PAE. PV reduction percentage was greater in group A than in group B at 1 month (74.1% ± 4.3 vs 63.7% ± 3.5; P = .006) and 3 months (61.5% ± 6.7 vs 46.1% ± 3.8; P = .001) after PAE. Proportion of prostate ischemic volume was greater in group A than in group B (75.3% ± 3.0 vs 62.0% ± 7.1; P = .006) at 1 month after PAE. Proportion of prostate ischemic volume at 1 month positively correlated with PV percentage reduction at 3 months in group A (r = 0.840, P = .036) and group B (r = 0.844, P = .035). There were no complications or nontarget embolization to surrounding organs after the procedures.<br />Conclusions: In a canine model, PAE with bleomycin-eluting microspheres was feasible and well tolerated and caused ischemic necrosis and reduction in PV.<br /> (Copyright © 2019 SIR. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1535-7732
Volume :
31
Issue :
5
Database :
MEDLINE
Journal :
Journal of vascular and interventional radiology : JVIR
Publication Type :
Academic Journal
Accession number :
32305243
Full Text :
https://doi.org/10.1016/j.jvir.2019.11.028