Back to Search
Start Over
Acute success and safety of the second-generation PVAC GOLD phased RF ablation catheter for atrial fibrillation.
- Source :
-
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2021 Mar; Vol. 60 (2), pp. 261-270. Date of Electronic Publication: 2020 Apr 06. - Publication Year :
- 2021
-
Abstract
- Purpose: The second-generation multi-electrode catheter, pulmonary vein ablation catheter (PVAC) GOLD, was designed to improve the delivery of phased radiofrequency energy and reduce procedure times using a 'single-shot' approach for pulmonary vein isolation (PVI), while retaining efficacy and safety. This large registry presents acute success rates and safety outcomes in a daily practice setting.<br />Methods: A total of 1017 patients undergoing first-time ablation for atrial fibrillation (AF) using PVAC GOLD were included, 644 patients with paroxysmal AF and 373 patients with non-paroxysmal AF, divided into 175 patients receiving PVI only and 198 patients receiving PVI with additional substrate modification.<br />Results: High and comparable percentages of successful PVI could be achieved in all groups (98%, 95% and 99%; p = 0.108). The median total procedure time for all groups was 90 min [70-100]. As expected, the total procedure, ablation and fluoroscopy time were significantly longer in the PVI + substrate modification group compared with the PVI-only cases (all p < 0.001), but not between the PVI-only groups (p = 0.306, p = 0.088, p = 0.233, respectively). A total of 44 complications were observed in 43 patients (4.2%). Major complications were seen in 19 patients (1.87%) and non-major procedure-related complications were seen in 25 patients (2.46%). Complications leaving permanent sequelae were rare and occurred in only four patients (0.39%). Complications did not differ between groups (p = 0.199, p = 0.438, p = 0.240 and p = 0.465 respectively).<br />Conclusion: PVAC GOLD performs successful PVI, while reducing procedure times and retaining safety for paroxysmal, persistent and long-standing persistent AF. Safety was unaffected by additional substrate modification.
Details
- Language :
- English
- ISSN :
- 1572-8595
- Volume :
- 60
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
- Publication Type :
- Academic Journal
- Accession number :
- 32253598
- Full Text :
- https://doi.org/10.1007/s10840-020-00728-8