Back to Search
Start Over
Systematic review and meta-analysis of published studies on endovascular repair of thoracoabdominal aortic aneurysms with the t-Branch off-the-shelf multibranched endograft.
- Source :
-
Journal of vascular surgery [J Vasc Surg] 2020 Aug; Vol. 72 (2), pp. 716-725.e1. Date of Electronic Publication: 2020 Apr 01. - Publication Year :
- 2020
-
Abstract
- Background: Endovascular treatment of thoracoabdominal aortic aneurysms is becoming increasingly popular in clinical practice, mainly because of its reduced perioperative mortality and morbidity. However, the custom-made stent graft platform that companies offer requires detailed preoperative planning and production time that can take up to 12 weeks. This may delay surgery in elective patients and is not an option for urgent or emergent cases. To surpass this limitation, the t-Branch (Cook Medical, Bloomington, Ind) was launched in 2012 in Europe as the first off-the-shelf standardized multibranched endograft for the endovascular treatment of thoracoabdominal aneurysms. Our aim was to systematically evaluate all published experience with this commercially available off-the-shelf thoracoabdominal stent graft.<br />Methods: We performed a systematic inquiry of the medical databases to identify all published studies that reported on the outcomes of patients treated with the t-Branch stent graft and then conducted a qualitative synthesis and meta-analysis of the results. The main end points studied were technical success, mortality, major stroke, spinal cord ischemia, primary branch patency, and renal insufficiency during the first 30 days along with midterm mortality and reintervention rate. We estimated pooled proportions and 95% confidence intervals (CIs).<br />Results: We identified seven retrospective studies published between 2014 and 2018, with a total of 197 patients (mean age, 72.3 ± 7 years; 70% male). Among 165 patients, 45% were symptomatic and 19% were treated for a ruptured aortic aneurysm. In 197 patients, pooled technical success was 92.75% (95% CI, 83.9%-98.7%), and in 10% of the cases, an early endoleak was detected (95% CI, 0%-43.7%). Early mortality was 5.8% (95% CI, 2.5%-10%), and major stroke was observed in 4% of the patients (95% CI, 0.96%-8.40%). The rate of spinal cord ischemia was 12.2% (95% CI, 4.1%-23.2%), with the rate of permanent paraplegia at 1.3% (95% CI, 0%-8.7%). Acute renal failure was 18.7% (95% CI, 9.1%-30.4%), whereas primary branch patency was calculated at 98.2% (95% CI, 96.7%-99.2%). Mean follow-up was 15 ± 7 months. During this time, midterm mortality (after 30 days) was 6.9% (95% CI, 2.44%-12.8%) and pooled reintervention rate was 5.7% (95% CI, 1.70%-11.4%).<br />Conclusions: This pooled analysis indicated good technical success rate after t-Branch endograft implantation, with acceptable mortality and neurologic complications despite a high rate of urgent procedures. Thoracoabdominal endovascular repair with the t-Branch endograft is a feasible and safe therapeutic option for elective and urgent patients.<br /> (Copyright © 2020 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Aortic Aneurysm, Thoracic mortality
Aortic Aneurysm, Thoracic physiopathology
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation mortality
Endovascular Procedures adverse effects
Endovascular Procedures mortality
Female
Humans
Male
Middle Aged
Postoperative Complications mortality
Postoperative Complications therapy
Risk Assessment
Risk Factors
Time Factors
Treatment Outcome
Vascular Patency
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Prosthesis Design
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6809
- Volume :
- 72
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 32247700
- Full Text :
- https://doi.org/10.1016/j.jvs.2020.01.049