Back to Search Start Over

Development and validation of a liquid chromatography/tandem mass spectrometry method to quantify metabolites of phthalates, including di-2-ethylhexyl terephthalate (DEHTP) and bisphenol A, in human urine.

Authors :
Frigerio G
Campo L
Mercadante R
Santos PM
Missineo P
Polledri E
Fustinoni S
Source :
Rapid communications in mass spectrometry : RCM [Rapid Commun Mass Spectrom] 2020 Jul 15; Vol. 34 (13), pp. e8796.
Publication Year :
2020

Abstract

Rationale: Several phthalates and bisphenol A are endocrine-disrupting chemicals (EDCs). Recently, their use has been partially restricted and less toxic compounds, such as di-2-ethylhexyl terephthalate (DEHTP), have been placed on the market. The aim of this work was to develop and validate a method for the simultaneous quantitation of bisphenol A and urinary metabolites of phthalates, including DEHTP.<br />Methods: An isotopic dilution high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method for the determination of bisphenol A (BPA), monobenzyl phthalate (MBzP), mono-2-ethyl-5-carboxypentyl phthalate (MECPP), mono-2-ethyl-5-carboxypentyl terephthalate (MECPTP), mono-2-ethyl-5-hydroxyhexyl terephthalate (MEHHTP), monoethyl phthalate (MEP), and mono-n/i-butyl phthalates (MnBP/MiBP) in human urine was developed. A complete validation was carried out and the method was applied to 36 non-occupationally exposed adults.<br />Results: Limits of quantitation ranged from 0.02 (MECPP) to 1 μg/L (MnBP and MiBP). Relative standard deviations below 10% indicated a suitable precision; accuracy, evaluated using a standard reference material, ranged from 74.3% to 117.5%; isotopically labelled internal standards were suitable for correcting the matrix effect. The accuracy was confirmed by the successful participation in an external verification exercise. However, for terephthalates, the validation was incomplete due to the lack of reference materials and external verification. Levels of the investigated chemicals in subjects were in line with those previously reported.<br />Conclusions: An LC/MS/MS assay for the simultaneous measurement of BPA and phthalate metabolites in human urine was developed and validated; it is useful to investigate exposure in epidemiological studies involving the general population.<br /> (© 2020 John Wiley & Sons, Ltd.)

Details

Language :
English
ISSN :
1097-0231
Volume :
34
Issue :
13
Database :
MEDLINE
Journal :
Rapid communications in mass spectrometry : RCM
Publication Type :
Academic Journal
Accession number :
32246863
Full Text :
https://doi.org/10.1002/rcm.8796