Comparison of rectal dose reduction by a hydrogel spacer among 3D conformal radiotherapy, volumetric-modulated arc therapy, helical tomotherapy, CyberKnife and proton therapy.

Authors :
Saito M
Suzuki T
Sugama Y
Marino K
Sano N
Komiyama T
Aoki S
Maehata Y
Yoshizawa K
Ashizawa K
Suzuki H
Ueda K
Miyasaka Y
Araya M
Takahashi H
Onishi H
Source :
Journal of radiation research [J Radiat Res] 2020 May 22; Vol. 61 (3), pp. 487-493.
Publication Year :
2020

Abstract

This study aimed to evaluate the rectal dose reduction with hydrogel spacer in 3D conformal radiotherapy (3DCRT), volumetric modulated arc therapy (VMAT), helical tomotherapy (HT), CyberKnife (CK) and proton therapy. Twenty patients who had hydrogel spacer for prostate radiotherapy were retrospectively enrolled. Computed tomography (CT) images with or without hydrogel spacer were used to evaluate rectal dose reduction. In total, 200 plans (20 patients × 2 CT images × 5 techniques) were created using the following criteria: 3DCRT, VMAT and HT [76 Gy/38 fractions (Fr), planning target volume (PTV) D50%], CK (36.25 Gy/5 Fr, PTV D95%) and proton therapy (63 GyE/21 Fr, PTV D50%). Rectal dose reduction was evaluated using low-/middle-dose (D20%, D50% and D80%) and high-dose (D2%) ranges. Rectal dose reduction of each dose index was compared for each technique. Significant rectal dose reduction (P < 0.001) between the treatment plans on pre- and post-CT images were achieved for all modalities for D50%, D20% and D2%. In particular, the dose reduction of high-dose (D2%) ranges were -40.61 ± 11.19, -32.44 ± 5.51, -25.90 ± 9.89, -13.63 ± 8.27 and -8.06 ± 4.19%, for proton therapy, CK, HT, VMAT and 3DCRT, respectively. The area under the rectum dose-volume histogram curves were 34.15 ± 3.67 and 34.36 ± 5.24% (P = 0.7841) for 3DCRT with hydrogel spacer and VMAT without hydrogel spacer, respectively. Our results indicated that 3DCRT with hydrogel spacer would reduce the medical cost by replacing the conventional VMAT without spacer for prostate cancer treatment, from the point of view of the rectal dose. For the high-dose gradient region, proton therapy and SBRT with CK showed larger rectal dose reduction than other techniques.<br /> (© The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.)

Details

Language :
English
ISSN :
1349-9157
Volume :
61
Issue :
3
Database :
MEDLINE
Journal :
Journal of radiation research
Publication Type :
Academic Journal
Accession number :
32211861
Full Text :
https://doi.org/10.1093/jrr/rraa013