Back to Search Start Over

Kinetic analysis of HER2-binding ABY-025 Affibody molecule using dynamic PET in patients with metastatic breast cancer.

Authors :
Alhuseinalkhudhur A
Lubberink M
Lindman H
Tolmachev V
Frejd FY
Feldwisch J
Velikyan I
Sörensen J
Source :
EJNMMI research [EJNMMI Res] 2020 Mar 23; Vol. 10 (1), pp. 21. Date of Electronic Publication: 2020 Mar 23.
Publication Year :
2020

Abstract

Background: High expression of human epidermal growth factor receptor type 2 (HER2) represents an aggressive subtype of breast cancer. Anti-HER2 treatment requires a theragnostic approach wherein sufficiently high receptor expression in biopsy material is mandatory. Heterogeneity and discordance of HER2 expression between primary tumour and metastases, as well as within a lesion, present a complication for the treatment and require multiple biopsies. Molecular imaging using the HER2-targeting Affibody peptide ABY-025 radiolabelled with <superscript>68</superscript> Ga-gallium for PET/CT is currently under investigation as a non-invasive tool for whole-body evaluation of metastatic HER2 expression. Initial studies demonstrated a high correlation between <superscript>68</superscript> Ga-ABY-025 standardized uptake values (SUVs) and histopathology. However, detecting small liver lesions might be compromised by high background uptake. This study aimed to explore the applicability of kinetic modelling and parametric image analysis for absolute quantification of <superscript>68</superscript> Ga-ABY-025 uptake and HER2-receptor expression and how that relates to static SUVs.<br />Methods: Dynamic <superscript>68</superscript> Ga-ABY-025 PET of the upper abdomen was performed 0-45 min post-injection in 16 patients with metastatic breast cancer. Five patients underwent two examinations to test reproducibility. Parametric images of tracer delivery (K <subscript>1</subscript> ) and irreversible binding (K <subscript>i</subscript> ) were created with an irreversible two-tissue compartment model and Patlak graphical analysis using an image-derived input function from the descending aorta. A volume of interest (VOI)-based analysis was performed to validate parametric images. SUVs were calculated from 2 h and 4 h post-injection static whole-body images and compared to K <subscript>i</subscript> .<br />Results: Characterization of HER2 expression in smaller liver metastases was improved using parametric images. K <subscript>i</subscript> values from parametric images agreed very well with VOI-based gold standard (R <superscript>2</superscript> > 0.99, p < 0.001). SUVs of metastases at 2 h and 4 h post-injection were highly correlated with K <subscript>i</subscript> values from both the two-tissue compartment model and Patlak method (R <superscript>2</superscript> = 0.87 and 0.95, both p < 0.001). <superscript>68</superscript> Ga-ABY-025 PET yielded high test-retest reliability (relative repeatability coefficient for Patlak 30% and for the two-tissue compartment model 47%).<br />Conclusion: <superscript>68</superscript> Ga-ABY-025 binding in HER2-positive metastases was well characterized by irreversible two-tissue compartment model wherein K <subscript>i</subscript> highly correlated with SUVs at 2 and 4 h. Dynamic scanning with parametric image formation can be used to evaluate metastatic HER2 expression accurately.

Details

Language :
English
ISSN :
2191-219X
Volume :
10
Issue :
1
Database :
MEDLINE
Journal :
EJNMMI research
Publication Type :
Academic Journal
Accession number :
32201920
Full Text :
https://doi.org/10.1186/s13550-020-0603-9