Back to Search Start Over

Trajectory-based VMAT for cranial targets with delivery at shortened SAD.

Authors :
Mullins J
Renaud MA
Heng V
Ruo R
DeBlois F
Seuntjens J
Source :
Medical physics [Med Phys] 2020 Jul; Vol. 47 (7), pp. 3103-3112. Date of Electronic Publication: 2020 Apr 27.
Publication Year :
2020

Abstract

Introduction: Trajectory-based volumetric modulated arc therapy (tr-VMAT) treatment plans enable the option for noncoplanar delivery yielding steeper dose gradients and increased sparing of critical structures compared to conventional treatment plans. The addition of translational couch motion to shorten the effective source-to-axis distance (SAD) may result in improved delivery precision and an increased effective dose rate. In this work, tr-VMAT treatment plans using a noncoplanar "baseball stitch" trajectory were implemented, applied to patients presented with cranial targets, and compared to the clinical treatment plans.<br />Methods: A treatment planning workflow was implemented: (a) beamlet doses were calculated for control points defined along a baseball stitch trajectory using a collapsed-cone convolution-superposition algorithm; (b) VMAT treatment plans were optimized using the column generation approach; (c) a final dose distribution was calculated in Varian Eclipse using the analytical anisotropic algorithm by importing the optimized treatment plan parameters. Tr-VMAT plans were optimized for ten patients presented with cranial targets at both standard and shortened SAD, and compared to the clinical treatment plans through isodose distributions, dose-volume histograms, and dosimetric indices. The control point specifications of the optimized tr-VMAT plans were used to estimate the delivery time.<br />Results: The optimized tr-VMAT plans with both shortened and standard SAD delivery yielded a comparable plan quality to the clinical treatment plans. A statistically significant benefit was observed for dose gradient index and monitor unit efficiency for shortened SAD tr-VMAT plans, while improved target volume conformity was observed for the clinical treatment plan (P ≤ 0.05). A clear dosimetric benefit was not demonstrated between tr-VMAT delivery at shortened SAD compared to standard SAD, but shortened SAD delivery yielded a fraction size-dependent reduction in the estimated delivery time.<br />Conclusion: The implementation of "baseball stitch" tr-VMAT treatment plans to patients presented with cranial targets demonstrated comparable plan quality to clinical treatment plans. The delivery at shortened SAD produced a fraction size-dependent decrease in estimated delivery time.<br /> (© 2020 American Association of Physicists in Medicine.)

Details

Language :
English
ISSN :
2473-4209
Volume :
47
Issue :
7
Database :
MEDLINE
Journal :
Medical physics
Publication Type :
Academic Journal
Accession number :
32198933
Full Text :
https://doi.org/10.1002/mp.14151