Evaluation of selected pharmaceuticals and personal care products in water matrix using ion trap mass spectrometry: A simple weighted calibration curve approach.
- Source :
-
Journal of pharmaceutical and biomedical analysis [J Pharm Biomed Anal] 2020 Jun 05; Vol. 185, pp. 113214. Date of Electronic Publication: 2020 Feb 26. - Publication Year :
- 2020
-
Abstract
- A novel analytical method is presented for 12 target pharmaceutical and personal care products (PPCPs), belonging to different classes like antibiotics, non-steroid anti-inflammatory drugs, parabens, UV-filters, plasticizer, and antibacterials. The method development comprises of solid-phase extraction (SPE) with lipophilic-hydrophilic material balanced Oasis HLB cartridge, followed by reverse-phase liquid chromatography interfaced to linear ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization. Chromatographic separation was achieved with a gradient elution of 25 min run time using 5 mM ammonium acetate buffer with pH adjustment using acetic acid. In addition, cost effective organic solvent with buffer used together as the mobile phase with Chromatopak C <subscript>18</subscript> column (150 mm × 4 mm, 5-μm,) in negative ionization mode. Recoveries ranged from 61.74 % to 119.89 % for most of the compounds. Matrix-matched calibration curves were used for counterbalancing the matrix effects for all the analytes, and ibuprofen D3 internal standard was used for assessing the effectiveness of extraction technique and monitoring the recovery of sample analysis. Simple empirical weighted linear regression curve technique was adopted practically for each analysis in enhancing the analyte accuracy at lower quantification level. The 1/x <superscript>2</superscript> model was selected as the best suitable model for quantification of analytes, which can be evaluated by deviation from back-calculated concentration in terms of percentage relative error (%RE). Weighted calibration curves with regression value for most of the compounds were ≥ 0.98, except triclosan with a regression value ≥ 0.93. Precision showed as % relative standard deviation (%RSD) were always below 15.0 %. Accuracy-test was evaluated by the statistical one-sample t-test and no significant difference was observed between nominal and experimental value. The limit of quantification (LOQ) ranged from 3.0 ng/mL (BP1) to 1000 ng/mL (naproxen). Finally, the validated method was used for the first time to determine target analytes in surface water samples collected from Arkavathi river flowing across southern India's Bengaluru city.<br />Competing Interests: Declaration of Competing Interest No conflict of interest was reported by the authors.<br /> (Copyright © 2020 Elsevier B.V. All rights reserved.)
- Subjects :
- Anti-Bacterial Agents analysis
Anti-Inflammatory Agents, Non-Steroidal analysis
Calibration
Chromatography, High Pressure Liquid methods
Chromatography, High Pressure Liquid standards
Chromatography, Reverse-Phase methods
Chromatography, Reverse-Phase standards
Cosmetics analysis
India
Limit of Detection
Parabens analysis
Plasticizers analysis
Rivers
Solid Phase Extraction methods
Solid Phase Extraction standards
Tandem Mass Spectrometry standards
Water chemistry
Environmental Monitoring methods
Tandem Mass Spectrometry methods
Water analysis
Water Pollutants, Chemical analysis
Water Pollution, Chemical prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1873-264X
- Volume :
- 185
- Database :
- MEDLINE
- Journal :
- Journal of pharmaceutical and biomedical analysis
- Publication Type :
- Academic Journal
- Accession number :
- 32126444
- Full Text :
- https://doi.org/10.1016/j.jpba.2020.113214